Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications.

作者信息

Clauser Paola, Nagl Georg, Helbich Thomas H, Pinker-Domenig Katja, Weber Michael, Kapetas Panagiotis, Bernathova Maria, Baltzer Pascal A T

机构信息

Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.

Department for Radiology and Interventional Radiology, Landesklinikum Horn, Spitalgasse 10, 3580 Horn, Austria.

出版信息

Eur J Radiol. 2016 Dec;85(12):2161-2168. doi: 10.1016/j.ejrad.2016.10.004. Epub 2016 Oct 7.

Abstract

OBJECTIVES

To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications.

METHODS

IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients' history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions' characteristics and reading time were analysed.

RESULTS

Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P=0.510). Inter-reader differences were detected (P<0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P=0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25s, respectively).

CONCLUSION

Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

摘要

目的

评估广角数字乳腺断层合成(DBT)与全视野数字乳腺X线摄影(FFDM)相比,在微钙化检测和特征描述方面的诊断性能。

方法

本回顾性研究获得了机构审查委员会(IRB)的批准。我们选取了150例FFDM和DBT检查病例(50例经组织学证实为良性微钙化,50例为恶性微钙化,50例分类为乳腺影像报告和数据系统(BI-RADS)1类)。四位放射科医生在独立的检查环节中进行评估,且对患者病史和组织学情况不知情,判断微钙化的存在情况。对有微钙化的病例,使用BI-RADS分类评估其可见性、特征及可疑程度。计算检测率和诊断性能。分析可见性、病变特征及阅片时间。

结果

FFDM和DBT的检测率和可见性均良好,读者内差异无统计学意义(P = 0.510)。读者间差异有统计学意义(P < 0.018)。在FFDM或DBT上,只有两个病变未被任何一位读者检测到。DBT的诊断性能与FFDM相当,但读者间差异有统计学意义(P = 0.041)。发现描述符的使用存在较高的读者间变异性。DBT的阅片时间几乎是FFDM的两倍(分别为44秒和25秒)。

结论

广角DBT能够检测微钙化并进行特征描述,与FFDM相比无显著差异。存在读者间变异性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验