Suppr超能文献

一种用于诊断阻塞性睡眠呼吸暂停的新型睡眠监测系统的验证:与多导睡眠图的比较。

Validation of a novel sleep-monitoring system for diagnosing obstructive sleep apnea: A comparison with polysomnography.

作者信息

Meng Lili, Xu Huajun, Guan Jian, Yi Hongliang, Wu Hongmin, Yin Shankai

机构信息

Department of Otolaryngology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, P.R. China.

Department of Otolaryngology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, P.R. China; Otolaryngology Institute of Shanghai Jiao Tong University, Shanghai 200233, P.R. China.

出版信息

Exp Ther Med. 2016 Nov;12(5):2937-2941. doi: 10.3892/etm.2016.3721. Epub 2016 Sep 20.

Abstract

Overnight polysomnography (PSG) is currently the gold standard for diagnosing obstructive sleep apnea (OSA); however, it is time-consuming, expensive and uncomfortable for the patient. A micromovement sensitive mattress (MSM) sleep-monitoring system was developed as an alternative to PSG, however, there has yet to be a study verifying the accuracy of diagnosing OSA with this device. Therefore, the present study assessed the validity of the MSM sleep-monitoring system. Chinese Han participants who were suspected of having OSA were recruited between June 2013 and June 2014. The MSM sleep-monitoring system and PSG were utilized simultaneously overnight on each subject. The apnea-hypopnea index (AHI) was measured by the MSM sleep-monitoring system (AHI) and compared with that determined by PSG (AHI), revealing a significant correlation between the two values (r=0.97, P<0.001). Bland-Altman plots also indicated good agreement (97%) between MSM and PSG. Using an AHI cut-off of ≥5, ≥15 and ≥30 events/h, the sensitivity (specificity) of detecting an AHI of ≥5, ≥15, and ≥30 events/h were 94.9 (100%), 89.9 (96.9%) and 90.3% (94.9%), respectively. The areas under the receiver operating characteristic curve, which were used to differentiate an AHI of ≥5, ≥15 and ≥30 events/h in clinically diagnosed OSA, were 0.984, 0.982 and 0.980, respectively. Thus, the MSM sleeping system may accurately diagnose OSA in the Chinese Han population. Further community-based studies with larger sample sizes are warranted to confirm the validity of this MSM sleeping system.

摘要

夜间多导睡眠图(PSG)是目前诊断阻塞性睡眠呼吸暂停(OSA)的金标准;然而,它耗时、昂贵且让患者感到不适。一种微动敏感床垫(MSM)睡眠监测系统被开发出来作为PSG的替代方案,然而,尚未有研究验证使用该设备诊断OSA的准确性。因此,本研究评估了MSM睡眠监测系统的有效性。2013年6月至2014年6月招募了疑似患有OSA的中国汉族参与者。每位受试者在夜间同时使用MSM睡眠监测系统和PSG。通过MSM睡眠监测系统测量呼吸暂停低通气指数(AHI),并与PSG测定的AHI进行比较,发现两者之间存在显著相关性(r = 0.97,P < 0.001)。Bland - Altman图也表明MSM和PSG之间具有良好的一致性(97%)。使用AHI截断值≥5、≥15和≥30次/小时,检测AHI≥5、≥15和≥30次/小时的敏感性(特异性)分别为94.9(100%)、89.9(96.9%)和90.3%(94.9%)。用于区分临床诊断的OSA中AHI≥5、≥15和≥30次/小时的受试者工作特征曲线下面积分别为0.984、0.982和0.980。因此,MSM睡眠系统可能在中国汉族人群中准确诊断OSA。有必要进行进一步的基于社区的大样本研究来证实该MSM睡眠系统的有效性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/688e/5103728/2ddb92deae61/etm-12-05-2937-g00.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验