Overnight polysomnography (PSG) is currently the gold standard for diagnosing obstructive sleep apnea (OSA); however, it is time-consuming, expensive and uncomfortable for the patient. A micromovement sensitive mattress (MSM) sleep-monitoring system was developed as an alternative to PSG, however, there has yet to be a study verifying the accuracy of diagnosing OSA with this device. Therefore, the present study assessed the validity of the MSM sleep-monitoring system. Chinese Han participants who were suspected of having OSA were recruited between June 2013 and June 2014. The MSM sleep-monitoring system and PSG were utilized simultaneously overnight on each subject. The apnea-hypopnea index (AHI) was measured by the MSM sleep-monitoring system (AHI) and compared with that determined by PSG (AHI), revealing a significant correlation between the two values (r=0.97, P<0.001). Bland-Altman plots also indicated good agreement (97%) between MSM and PSG. Using an AHI cut-off of ≥5, ≥15 and ≥30 events/h, the sensitivity (specificity) of detecting an AHI of ≥5, ≥15, and ≥30 events/h were 94.9 (100%), 89.9 (96.9%) and 90.3% (94.9%), respectively. The areas under the receiver operating characteristic curve, which were used to differentiate an AHI of ≥5, ≥15 and ≥30 events/h in clinically diagnosed OSA, were 0.984, 0.982 and 0.980, respectively. Thus, the MSM sleeping system may accurately diagnose OSA in the Chinese Han population. Further community-based studies with larger sample sizes are warranted to confirm the validity of this MSM sleeping system.
夜间多导睡眠图(PSG)是目前诊断阻塞性睡眠呼吸暂停(OSA)的金标准;然而,它耗时、昂贵且让患者感到不适。一种微动敏感床垫(MSM)睡眠监测系统被开发出来作为PSG的替代方案,然而,尚未有研究验证使用该设备诊断OSA的准确性。因此,本研究评估了MSM睡眠监测系统的有效性。2013年6月至2014年6月招募了疑似患有OSA的中国汉族参与者。每位受试者在夜间同时使用MSM睡眠监测系统和PSG。通过MSM睡眠监测系统测量呼吸暂停低通气指数(AHI),并与PSG测定的AHI进行比较,发现两者之间存在显著相关性(r = 0.97,P < 0.001)。Bland - Altman图也表明MSM和PSG之间具有良好的一致性(97%)。使用AHI截断值≥5、≥15和≥30次/小时,检测AHI≥5、≥15和≥30次/小时的敏感性(特异性)分别为94.9(100%)、89.9(96.9%)和90.3%(94.9%)。用于区分临床诊断的OSA中AHI≥5、≥15和≥30次/小时的受试者工作特征曲线下面积分别为0.984、0.982和0.980。因此,MSM睡眠系统可能在中国汉族人群中准确诊断OSA。有必要进行进一步的基于社区的大样本研究来证实该MSM睡眠系统的有效性。