The purpose was to compare the accuracy of Miniaci method using picture archiving and communication system (PACS) with a cable method in high tibial osteotomy (HTO).
This study analyzed 47 patients (52 knees) with varus deformity and medial osteoarthritis. From 2007 to 2013, patients underwent HTO using either a cable method (20 knees) or Miniaci method based on a PACS image (32 knees). In the cable method, the 62.5% point of the mediolateral tibial plateau width was located using an electrocautery cord under fluoroscopy (cable group). The Miniaci method used preoperative radiographs to shift the weight bearing axis (PACS group). Full-length lower limb radiographs obtained preoperatively and at the sixth postoperative week were used to compare the percentage of crossing point of the weight bearing line on the tibial plateau with respect to the medial border.
The weight bearing line on the tibial plateau was corrected from a preoperative 11.0±7.0% to a postoperative 47.2±7.4% in the cable group and from 12.7±4.9% to 59.5±5.3% in the PACS group. The mechanical femorotibial angle was corrected from varus 8.9±3.7° to valgus 0.3±4.0° in the cable group and from varus 9.0±3.3° to valgus 2.9±2.6° in the PACS group.
In HTO, correction based on the Miniaci method using a PACS was more accurate than correction using the cable method.
本研究旨在比较在高位胫骨截骨术(HTO)中,使用图像存档与通信系统(PACS)的Miniaci方法与缆线法的准确性。
本研究分析了47例(52膝)患有内翻畸形和内侧骨关节炎的患者。在2007年至2013年期间,患者接受了HTO手术,其中20膝采用缆线法,32膝采用基于PACS图像的Miniaci方法。在缆线法中,在透视下使用电灼线确定胫骨干骺端宽度的62.5%点(缆线组)。Miniaci方法使用术前X线片来移动负重轴(PACS组)。术前及术后第六周获得的下肢全长X线片用于比较负重线在胫骨平台上相对于内侧缘的交叉点百分比。
缆线组胫骨平台上的负重线从术前的11.0±7.0%矫正至术后的47.2±7.4%,PACS组从12.7±4.9%矫正至59.5±5.3%。缆线组机械性股胫角从内翻8.9±3.7°矫正至外翻0.3±4.0°,PACS组从内翻9.0±3.3°矫正至外翻2.9±2.6°。
在HTO中,基于使用PACS的Miniaci方法的矫正比缆线法更准确。