Suppr超能文献

后上颌植入即刻负重混合自攻型种植体的稳定性发展:一项随机对照试验的1年结果

Stability Development of Immediately Loaded Hybrid Self-Tapping Implants Inserted in the Posterior Maxilla: 1-Year Results of a Randomized Controlled Trial.

作者信息

Todorovic Vladimir S, Vasovic Miroslav, Beetge Mia-Michaela, van Zyl Andre W, Kokovic Vladimir

机构信息

1   Oral Surgery Department, School of Dental Medicine, University of Belgrade, Serbia.

2   Department of Periodontics and Oral Medicine, School of Dentistry, University of Pretoria, South Africa.

出版信息

J Oral Implantol. 2017 Feb;43(1):33-38. doi: 10.1563/aaid-joi-D-16-00143. Epub 2016 Nov 29.

Abstract

The objective of the present study was to elucidate stability development of immediately loaded hybrid self-tapping implants inserted in the posterior maxilla. Forty-eight hybrid self-tapping implants with a chemically modified surface (∅4.1; length: 8 mm) were inserted bilaterally in the maxillary first and second premolar and first molar sites of 8 patients. In each patient, both sides of the maxilla were assigned randomly to either immediate (IL) or early (EL) loading group. Implant stability was evaluated by means of resonance frequency analysis immediately after implant placement and after 1, 2, 3, 4, 5, 6, 12, 26, and 52 weeks. High values of primary stability were found in both groups (71.91 ± 6.52 implant stability quotient [ISQ] in IL group; 73.87 ± 6.5 ISQ in EL group), with significant differences between the groups at the different time points. Initial decrease in stability was observed between the first and fifth weeks in the IL group and between the first and third weeks for the EL group. In the IL group 1 implant was removed after 3 weeks due to lack of stability. Early results of this study showed the ability of hybrid self-tapping dental implants with a chemically modified surface to achieve sufficient primary stability and to maintain high values of secondary implant stability in bone type 3 and 4, even when loaded immediately. Minimal alterations in stability were observed for both investigated groups, but the EL group showed faster recovery after an initial drop in stability.

摘要

本研究的目的是阐明植入上颌后牙区的即刻负载混合型自攻式种植体的稳定性发展情况。将48枚具有化学改性表面的混合型自攻式种植体(直径4.1;长度:8 mm)双侧植入8例患者的上颌第一、第二前磨牙以及第一磨牙部位。在每位患者中,上颌两侧随机分配至即刻负载(IL)组或早期负载(EL)组。在种植体植入后即刻以及1、2、3、4、5、6、12、26和52周后,通过共振频率分析评估种植体稳定性。两组均发现较高的初期稳定性(IL组种植体稳定性商数[ISQ]为71.91±6.52;EL组为73.87±6.5),在不同时间点两组之间存在显著差异。IL组在第1周和第5周之间以及EL组在第1周和第3周之间观察到稳定性的初始下降。在IL组中,1枚种植体在3周后因稳定性不足而被取出。本研究的早期结果表明,具有化学改性表面的混合型自攻式牙种植体即使在即刻负载的情况下,也能够在3型和4型骨中获得足够的初期稳定性并维持较高的种植体二期稳定性值。两个研究组的稳定性变化均很小,但EL组在稳定性初始下降后显示出更快的恢复。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验