• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Rib cage vs. abdominal displacement in dogs during forced oscillation to 32 Hz.

作者信息

Boynton B R, Glass G, Frantz I D, Fredberg J J

机构信息

Department of Pediatrics, New England Medical Center, Boston, Massachusetts.

出版信息

J Appl Physiol (1985). 1989 Oct;67(4):1472-8. doi: 10.1152/jappl.1989.67.4.1472.

DOI:10.1152/jappl.1989.67.4.1472
PMID:2793751
Abstract

Allen et al. (J. Clin. Invest. 76: 620-629, 1985) reported that during oscillatory forcing the base of isolated canine lungs distends preferentially relative to the apex as frequency and tidal volume increase. The tendency toward such nonuniform phasic lung distension might influence phasic displacement of the rib cage (RC) relative to the abdomen (ABD). To test this hypothesis we measured RC and ABD displacement in four anesthetized dogs during forced oscillation. Sinusoidal volume changes were delivered through a tracheostomy at 1-32 Hz and measured by body plethysmography. RC and ABD displacements were measured by inductive plethysmography. During oscillation with air at fixed tidal volumes (10-80 ml) RC, normalized to unity at 1 Hz, increased to 2.06-2.22 at 8 Hz (P less than 0.001) and then decreased to 1.06-1.35 (P less than 0.0025) at 32 Hz. ABD, normalized to unity at 1 Hz, was 1.12-1.16 at 4 Hz (P less than 0.001) and decreased to 0.12-0.14 at 32 Hz (P less than 0.001). Displacement of ABD relative to RC did not increase systematically with increasing tidal volume during sinusoidal forcing at any frequency. Thus we found no discernible influence of nonuniform phasic lung distension on chest wall behavior. We infer that in the dog the nonuniform mechanical behavior of the chest wall dominates the nonuniform (but opposing) mechanical tendency of the lung.

摘要

相似文献

1
Rib cage vs. abdominal displacement in dogs during forced oscillation to 32 Hz.
J Appl Physiol (1985). 1989 Oct;67(4):1472-8. doi: 10.1152/jappl.1989.67.4.1472.
2
Rib cage versus abdominal displacement in rabbits during forced oscillations to 30 Hz.
J Appl Physiol (1985). 1987 Jul;63(1):309-14. doi: 10.1152/jappl.1987.63.1.309.
3
Chest wall impedance partitioned into rib cage and diaphragm-abdominal pathways.胸壁阻抗分为胸廓和膈肌-腹部通路。
J Appl Physiol (1985). 1989 Jan;66(1):350-9. doi: 10.1152/jappl.1989.66.1.350.
4
Regional distribution of chest wall displacements in infants during high-frequency ventilation.高频通气时婴儿胸壁位移的区域分布。
J Appl Physiol (1985). 2019 Apr 1;126(4):928-933. doi: 10.1152/japplphysiol.01086.2018. Epub 2019 Feb 7.
5
Regional coupling between chest wall and lung expansion during HFV: a positron imaging study.高频通气期间胸壁与肺扩张之间的区域耦合:一项正电子成像研究。
J Appl Physiol (1985). 1993 May;74(5):2242-52. doi: 10.1152/jappl.1993.74.5.2242.
6
Changes in the contribution of the rib cage to tidal breathing during infancy.婴儿期胸廓对潮式呼吸贡献的变化。
Am Rev Respir Dis. 1990 Apr;141(4 Pt 1):922-5. doi: 10.1164/ajrccm/141.4_Pt_1.922.
7
Effects of mean airway pressure and tidal volume on lung and chest wall mechanics in the dog.平均气道压和潮气量对犬肺与胸壁力学的影响。
J Appl Physiol (1985). 1993 May;74(5):2286-93. doi: 10.1152/jappl.1993.74.5.2286.
8
Chest wall mechanics during artificial ventilation.人工通气期间的胸壁力学
J Appl Physiol. 1975 Apr;38(4):576-80. doi: 10.1152/jappl.1975.38.4.576.
9
Ventilatory effectiveness of high-frequency oscillation applied to the body surface.应用于体表的高频振荡的通气有效性。
J Appl Physiol (1985). 1987 Jun;62(6):2410-5. doi: 10.1152/jappl.1987.62.6.2410.
10
Effect of negative abdominal pressure on regional lung volumes in supine dogs.腹部负压对仰卧位犬肺局部容积的影响。
Respir Physiol. 1976 Apr;26(2):213-21. doi: 10.1016/0034-5687(76)90099-2.