Ventilatory effectiveness of high-frequency oscillation applied to the body surface.

作者信息

Fuyuki T, Suzuki S, Sakurai M, Sasaki H, Butler J P, Takishima T

出版信息

J Appl Physiol (1985). 1987 Jun;62(6):2410-5. doi: 10.1152/jappl.1987.62.6.2410.

Abstract

To determine the ventilatory effectiveness of high-frequency oscillation (HFO) at different sites on the body surface, we applied HFO separately to the abdomen, the rib cage, or the whole body in eight anesthetized and paralyzed dogs. Test frequencies were 5, 7, 9, and 11 Hz with tidal volume kept constant at 2.5 ml/kg. During HFO application to the abdomen, we observed significantly higher arterial O2 partial pressure (P less than 0.05) at 5, 7, and 9 Hz and lower arterial CO2 partial pressure (P less than 0.05) at 7, 9, and 11 Hz than with rib cage or whole-body HFO. There was no significant difference in blood gases between rib cage and whole-body HFO. Thus, using blood gases as an index of ventilatory effectiveness, the present study showed that HFO applied at the abdomen was the most effective of the three kinds of body surface HFO. In comparison to rib cage or whole-body application, abdominal HFO was accompanied by substantial paradoxical movement of the diaphragm and rib cage. The associated lung distortion may result in pendelluft, which in turn may be the mechanism for increased ventilatory effectiveness with abdominal application of HFO.