Suppr超能文献

种植体支持的金属烤瓷固定义齿中修复体适合性对饰面瓷折裂(崩瓷)的影响:体外初步试验。

Influence of misfit on the occurrence of veneering porcelain fractures (chipping) in implant-supported metal-ceramic fixed dental prostheses: an in vitro pilot trial.

机构信息

Department of Prosthodontics, Centre for Specialist Dental Care, Public Dental Care, Lund, Sweden.

Department of Materials Science and Technology, Faculty of Odontology, Malmö University, Malmö, Sweden.

出版信息

Clin Oral Implants Res. 2017 Nov;28(11):1381-1387. doi: 10.1111/clr.12997. Epub 2016 Dec 19.

Abstract

OBJECTIVE

Technical complications such as veneer fractures are more common in implant-supported than tooth-supported restorations. The underlying causes have not been fully identified. The aim of this study was to evaluate whether misfit between the restoration and the implant may affect the risk of veneer fractures.

MATERIALS AND METHODS

Twenty standardized five-unit implant-supported metal-ceramic fixed dental prostheses (FDP)s were manufactured and fixed in acrylic blocks. The test group consisted of ten FDPs fixed with a 150-μm misfit at the distal abutment. The remaining ten FDPs were fixed without misfit and acted as a control group. All FDPS underwent cyclic loading for a total of 100,000 cycles at 30-300 N. The FDPs were checked for cracks or chip-off fractures regularly. After cyclic load, the retorque value of all abutment screws was checked.

RESULTS

Cracks within the veneering porcelain were noted in nine FDPs in the test group and one FDP in the control group. This difference was statistically significant (P < 0.001). Fractures of the veneering porcelain occurred in three FDPs in the test group. No fractures occurred in the control group. This difference was not statistically significant. There were no significant differences in retorque values neither between the groups nor between different abutment positions in the FDPs.

CONCLUSIONS

Within the limitations of this in vitro pilot trial, it is suggested that misfit between a restoration and the supporting implant may increase the risk of cracking and/or chipping of the veneering porcelain for metal-ceramic FDPs.

摘要

目的

与牙支持修复体相比,种植体支持修复体更容易出现贴面碎裂等技术并发症。但其根本原因尚未完全明确。本研究旨在评估修复体与种植体之间的不匹配是否会影响贴面碎裂的风险。

材料与方法

制作并固定 20 个标准化的五单位种植体支持金属烤瓷固定义齿(FDP)于丙烯酸块中。实验组由 10 个在远中基牙有 150μm不匹配的 FDP 组成。其余 10 个 FDP 无不匹配,作为对照组。所有 FDP 均在 30-300 N 的范围内进行 100,000 次循环加载。定期检查 FDP 是否有裂缝或剥落性骨折。循环加载后,检查所有基牙螺丝的重新扭矩值。

结果

实验组的 9 个 FDP 和对照组的 1 个 FDP 出现了贴面瓷内的裂纹。这种差异具有统计学意义(P<0.001)。实验组的 3 个 FDP 发生了贴面瓷碎裂。对照组未发生碎裂。这种差异无统计学意义。实验组和对照组之间以及 FDP 的不同基牙位置之间的重新扭矩值均无显著差异。

结论

在本体外试验的限制范围内,建议修复体与支持种植体之间的不匹配可能会增加金属烤瓷 FDP 贴面出现裂缝和/或剥落的风险。