Yang Jingjing, Trela Jozef, Plaza Elzbieta
Department of Sustainable Development, Environmental Science and Engineering, Royal Institute of Technology (KTH), Teknikringen 76, 100-44 Stockholm, Sweden E-mail:
Water Sci Technol. 2016 Dec;74(12):2870-2878. doi: 10.2166/wst.2016.454.
Measurements of nitrous oxide were made at pilot- and full-scale plants to evaluate greenhouse gas emissions from one-step partial nitritation/anammox processes applied in moving bed biofilm reactors treating reject water. It was found that 0.51-1.29% and 0.35-1.33% of the total nitrogen loads in the pilot- and full-scale reactor, respectively, were emitted as nitrous oxide. Between 80 and 90% of nitrous oxide emissions were in gaseous form and the rest amount was found in the reactor effluent; over 90% of nitrous oxide emissions occurred in the aerated period and less than 8% in the non-aerated period in the full-scale study. Nitrous oxide productions/consumptions were closely related to aeration and the nitrogen loads applied in the system.
在中试规模和全尺寸工厂中对一氧化二氮进行了测量,以评估在移动床生物膜反应器处理垃圾渗滤液时应用的一步式部分亚硝化/厌氧氨氧化工艺产生的温室气体排放。结果发现,中试规模和全尺寸反应器中分别有0.51%-1.29%和0.35%-1.33%的总氮负荷以一氧化二氮的形式排放。80%至90%的一氧化二氮排放为气态形式,其余部分存在于反应器出水中;在全尺寸研究中,超过90%的一氧化二氮排放发生在曝气期,非曝气期的排放量不到8%。一氧化二氮的产生/消耗与曝气和系统中施加的氮负荷密切相关。