Yao S Z, Tan S L, Nie L H
Yao Xue Xue Bao. 1989;24(2):122-6.
A new method for the determination of dipyrone (analgin) using a piezoelectric quartz crystal as detector has been proposed. An iodine-potassium iodide solution is added to the sample and the frequency shift of the crystal immersed in the sample solution with respect to the blank is directly proportional to the concentration of dipyrone over a range from 2 x 10(-7) to 3 x 10(-6) mol/L at pH 3.5-6.5 according to the equation C (mol/L) = 6.85 x 10(-9) delta F (Hz). No significant interferences were caused by commonly met inorganic substances, amino acids and a number of other organic substances. The method has been suggested for determining dipyrone at ppm level and in micro-samples of mg or microliters level.
提出了一种以压电石英晶体为检测器测定安乃近的新方法。将碘化钾溶液加入样品中,在pH 3.5 - 6.5条件下,浸入样品溶液中的晶体相对于空白溶液的频率偏移在2×10⁻⁷至3×10⁻⁶mol/L范围内与安乃近浓度成正比,根据公式C(mol/L)= 6.85×10⁻⁹ΔF(Hz)。常见的无机物质、氨基酸和许多其他有机物质不会产生明显干扰。该方法适用于测定ppm级以及毫克或微升级微量样品中的安乃近。