Suppr超能文献

Assessing the feasibility of yttria-stabilized zirconia in novel designs as mandibular anterior fixed lingual retention after orthodontic treatment.

作者信息

Stout Matthew M, Cook Brian K, Arola Dwayne D, Fong Hanson, Raigrodski Ariel J, Bollen Anne-Marie

机构信息

Department of Orthodontics, University of Washington, Seattle, Wash.

Materials Science and Engineering, University of Washington, Seattle, Wash.

出版信息

Am J Orthod Dentofacial Orthop. 2017 Jan;151(1):63-73. doi: 10.1016/j.ajodo.2016.04.032.

Abstract

INTRODUCTION

The purpose of this study is to explore the feasibility of yttria-stabilized zirconia (Y-TZP) in fixed lingual retention as an alternative to stainless steel.

METHODS

Exploratory Y-TZP specimens were milled to establish design parameters. Next, the specimens were milled according to ASTM standard C1161-13 and subjected to 4-point flexural tests to determine material properties. Finite element analysis was used to evaluate 9 novel cross-sectional designs, which were compared with stainless steel wire. Each design was analyzed under loading conditions to determine von Mises and bond stresses. The most promising design was fabricated to assess the accuracy and precision of current CAD/CAM milling technology.

RESULTS

The superior design had a 1.0 × 0.5 mm semielliptical cross-section and was shown to be fabricated reliably. Overall, the milling indicated a maximum percent standard deviation of 9.3 and maximum percent error of 13.5 with a cost of $30 per specimen.

CONCLUSIONS

Y-TZP can be reliably milled to dimensions comparable with currently available metallic retainer wires. Further research is necessary to determine the success of the bonding protocol and the clinical longevity of Y-TZP fixed retainers. Advanced technology is necessary to connect the intraoral scan to an esthetic and patient-specific Y-TZP fixed retainer.