Suppr超能文献

一款10赫兹全球定位系统(GPS)装置在测量不同速度和距离(5 - 20米)下的穿梭速度时的准确性。

Accuracy of a 10 Hz GPS Unit in Measuring Shuttle Velocity Performed at Different Speeds and Distances (5 - 20 M).

作者信息

Beato Marco, Bartolini Davide, Ghia Gianluigi, Zamparo Paola

机构信息

Department of Neurological, Biomedical and Movement Sciences, University of Verona, Italy; Faculty of Health and Science, Department of Science and Technology, University of Suffolk, Ipswich, UK.

Department of Neurological, Biomedical and Movement Sciences, University of Verona, Italy.

出版信息

J Hum Kinet. 2016 Dec 15;54:15-22. doi: 10.1515/hukin-2016-0031. eCollection 2016 Dec 1.

Abstract

The aim of this study was to validate the accuracy of a 10 Hz GPS device (STATSports, Ireland) by comparing the instantaneous values of velocity determined with this device with those determined by kinematic (video) analysis (25 Hz). Ten male soccer players were required to perform shuttle runs (with 180° change of direction) at three velocities (slow: 2.2 m·s; moderate: 3.2 m·s; high: maximal) over four distances: 5, 10, 15 and 20 m. The experiments were video-recorded; the "point by point" values of speed recorded by the GPS device were manually downloaded and analysed in the same way as the "frame by frame" values of horizontal speed as obtained by video analysis. The obtained results indicated that shuttle distance was smaller in GPS than video analysis (p < 0.01). Shuttle velocity (shuttle distance/shuttle time) was thus smaller in GPS than in video analysis (p < 0.001); the percentage difference (bias, %) in shuttle velocity between methods was found to decrease with the distance covered (5 m: 9 ± 6%; 20 m: 3 ± 3%). The instantaneous values of speed were averaged; from these data and from data of shuttle time, the distance covered was recalculated; the error (criterion distance-recalculated distance) was negligible for video data (0.04 ± 0.28 m) whereas GPS data underestimated criterion distance (0.31 ± 0.55 m). In conclusion, the inaccuracy of this GPS unit in determining shuttle speed can be attributed to inaccuracy in determining the shuttle distance.

摘要

本研究的目的是通过比较使用该设备测定的瞬时速度值与通过运动学(视频)分析(25Hz)测定的瞬时速度值,来验证一款10Hz的GPS设备(STATSports,爱尔兰)的准确性。要求10名男性足球运动员在三种速度(慢速:2.2m·s;中速:3.2m·s;高速:最大速度)下,进行四个距离(5米、10米、15米和20米)的折返跑(方向改变180°)。实验进行了视频录制;将GPS设备记录的速度“逐点”值手动下载,并以与视频分析获得的水平速度“逐帧”值相同的方式进行分析。所得结果表明,GPS测定的折返跑距离小于视频分析的结果(p<0.01)。因此,GPS测定的折返跑速度(折返跑距离/折返跑时间)小于视频分析的结果(p<0.001);两种方法之间折返跑速度的百分比差异(偏差,%)随着所跑距离的增加而减小(5米:9±6%;20米:3±3%)。对速度的瞬时值进行了平均;根据这些数据和折返跑时间数据,重新计算了所跑距离;视频数据的误差(标准距离-重新计算的距离)可忽略不计(0.04±0.28米),而GPS数据低估了标准距离(0.31±0.55米)。总之,这款GPS设备在测定折返跑速度时的不准确性可归因于测定折返跑距离时的不准确性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fbd5/5187957/3b7bc5c2fc4c/j_hukin-2016-0031_fig_001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验