Rong W F, He J H, Meng R B, Ling W J, Hu J W, Qiu J J, Dong M
Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China.
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2016 Oct 20;34(10):777-781. doi: 10.3760/cma.j.issn.1001-9391.2016.10.016.
To investigate the method of portable gas chromatography-mass spectroscopy (GC-MS) for the determination of common volatile organic compounds in air. The static volumetric method was used, with highly purified nitrogen gas as the diluents gas, to prepare the mixed standard gas of common volatile organic compounds with various mass concentrations. A portable GC-MS handheld probe was used for sampling and measurement, retention time and characteristic ion were used for qualitative analysis, and the full-scan mode was used for quantitative analysis. The correlation coefficient of 12 volatile organic compounds determined by this method was higher than 0.999. The minimum detection mass concentration was 0.020.12 mg/m, and the minimum quantitative mass concentration was 0.070.40 mg/m. The relative standard deviation of precision was 4.10%~12.50%; the relative deviation of acetone, benzene, methylbenzene, and dimethylbenzene was-13.56% , 9.03% , -10.82% , and 8.67% , respectively. Portable GC-MS method can be used for the qualitative analysis and quantification of volatile organic compounds in occupational hazard factors and provide technical supports for identification of occupational hazard factors.
探讨便携式气相色谱 - 质谱联用仪(GC-MS)测定空气中常见挥发性有机化合物的方法。采用静态容量法,以高纯氮气作为稀释气,配制不同质量浓度的常见挥发性有机化合物混合标准气。使用便携式GC-MS手持式探头进行采样和测定,采用保留时间和特征离子进行定性分析,全扫描模式进行定量分析。该方法测定的12种挥发性有机化合物的相关系数均高于0.999。最低检测质量浓度为0.020.12mg/m³,最低定量质量浓度为0.070.40mg/m³。精密度相对标准偏差为4.10%~12.50%;丙酮、苯、甲苯和二甲苯的相对偏差分别为 -13.56%、9.03%、-10.82%和8.67%。便携式GC-MS法可用于职业危害因素中挥发性有机化合物的定性分析和定量测定,为职业危害因素识别提供技术支持。