Girometta M A, Loschi L, Ventura P, Canali S, Giachetti C, Zanolo G
Dipartimento di Chimica Analitica, Camillo Corvi, S.p.A., Piacenza, Italy.
Biomed Chromatogr. 1989 Sep;3(5):199-202. doi: 10.1002/bmc.1130030505.
A simple and precise method for the quantitation of epomediol in human plasma and urine is described. Each biological sample is added with the internal standard and applied directly to an Extrelut-1 solid-phase column. After absorption the column is eluted with chloroform and the eluate is evaporated to dryness. The residue, reconstituted in ethanol, is analysed by capillary gas chromatography. No interferences from possible metabolites or endogenous constituents can be noted. The method has been applied to human pharmacokinetic studies: the results of a subacute administration to volunteers are presented.
描述了一种简单且精确的定量测定人血浆和尿液中依泊二醇的方法。向每个生物样品中加入内标,然后直接应用于Extrelut - 1固相柱。吸附后,用氯仿洗脱该柱,洗脱液蒸发至干。将残留物用乙醇复溶后,通过毛细管气相色谱法进行分析。未发现可能的代谢物或内源性成分的干扰。该方法已应用于人体药代动力学研究:给出了对志愿者进行亚急性给药的结果。