Abstract

Macro-vascular artifacts are a common arterial spin labeling (ASL) finding in populations with prolonged arterial transit time (ATT) and result in vascular regions with spuriously increased cerebral blood flow (CBF) and tissue regions with spuriously decreased CBF. This study investigates whether there is an association between the spatial signal distribution of a single post-label delay ASL CBF image and ATT. In 186 elderly with hypertension (46% male, 77.4 ± 2.5 years), we evaluated associations between the spatial coefficient of variation (CoV) of a CBF image and ATT. The spatial CoV and ATT metrics were subsequently evaluated with respect to their associations with age and sex - two demographics known to influence perfusion. Bland-Altman plots showed that spatial CoV predicted ATT with a maximum relative error of 7.6%. Spatial CoV was associated with age (β = 0.163, p = 0.028) and sex (β = -0.204, p = 0.004). The spatial distribution of the ASL signal on a standard CBF image can be used to infer between-participant ATT differences. In the absence of ATT mapping, the spatial CoV may be useful for the clinical interpretation of ASL in patients with cerebrovascular pathology that leads to prolonged transit of the ASL signal to tissue.

摘要

大血管伪影是动脉自旋标记(ASL)在动脉通过时间(ATT)延长人群中的常见表现,会导致血管区域脑血流量(CBF)假性增加,组织区域CBF假性降低。本研究调查单次标记后延迟ASL CBF图像的空间信号分布与ATT之间是否存在关联。在186例高血压老年患者(男性占46%,年龄77.4±2.5岁)中,我们评估了CBF图像的空间变异系数(CoV)与ATT之间的关联。随后评估了空间CoV和ATT指标与年龄和性别的关联,年龄和性别是已知会影响灌注的两个人口统计学因素。Bland-Altman图显示,空间CoV预测ATT的最大相对误差为7.6%。空间CoV与年龄(β=0.163,p=0.028)和性别(β=-0.204,p=0.004)相关。标准CBF图像上ASL信号的空间分布可用于推断不同受试者之间的ATT差异。在没有ATT映射的情况下,空间CoV可能有助于对脑血管病变导致ASL信号向组织传递时间延长的患者进行ASL的临床解读。

相似文献

1
The spatial coefficient of variation in arterial spin labeling cerebral blood flow images.动脉自旋标记脑血流图像中的空间变异系数
J Cereb Blood Flow Metab. 2017 Sep;37(9):3184-3192. doi: 10.1177/0271678X16683690. Epub 2017 Jan 6.

引用本文的文献

本文引用的文献

8
Assessment of collateral flow in patients with cerebrovascular disorders.脑血管疾病患者侧支血流的评估。
J Neuroradiol. 2014 Oct;41(4):234-42. doi: 10.1016/j.neurad.2013.11.002. Epub 2013 Dec 30.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验