Highsmith M Jason, Kahle Jason T, Miro Rebecca M, Cress M Elaine, Quillen William S, Carey Stephanie L, Dubey Rajiv V, Mengelkoch Larry J
School of Physical Therapy & Rehabilitation Sciences, University of South Florida, Tampa, FL, USA; Extremity Trauma & Amputation Center of Excellence (EACE), U.S. Department of Veterans Affairs, Tampa, FL, USA; 319 Minimal Care Detachment, U.S. Army Reserves, Pinellas Park, FL, USA.
OP Solutions, Tampa, FL, USA; Prosthetic Design + Research, Tampa, FL, USA.
Technol Innov. 2016 Sep;18(2-3):185-191. doi: 10.21300/18.2-3.2016.185. Epub 2016 Sep 1.
The Continuous Scale-Physical Functional Performance-10 (CS-PFP-10) test consists of 10 standardized daily living tasks that evaluate overall physical functional performance and performance in five individual functional domains: upper body strength (UBS), upper body flexibility (UBF), lower body strength (LBS), balance and coordination (BAL), and endurance (END). This study sought to determine the concurrent validity of the CS-PFP-10 test and its functional domains that involve the lower extremities (LBS, BAL, or END) in comparison to measures that have established validity for use in persons with transfemoral amputation (TFA). Ten TFA patients functioning at K3 or higher (Medicare Functional Classification Level) completed the study. Participants were assessed performing the CS-PFP-10, Amputee Mobility Predictor (AMP), 75 m self-selected walking speed (75 m SSWS) test, timed down stair walking (DN stair time), and the limits of stability (LOS) balance test. Concurrent validity was assessed using correlation analysis. The AMP, 75 m SSWS, LOS, and the DN stair time tests were strongly correlated ( = ± 0.76 to 0.86) with their paired CS-PFP-10 domain score (LBS, BAL, or END) and CS-PFP-10 total score. These findings indicate that the lower limb and balance domains of the CS-PFP-10 are valid measures to assess the physical functional performance of TFA patients.
连续量表-身体功能表现-10(CS-PFP-10)测试由10项标准化的日常生活任务组成,这些任务评估整体身体功能表现以及五个个体功能领域的表现:上肢力量(UBS)、上肢灵活性(UBF)、下肢力量(LBS)、平衡与协调(BAL)以及耐力(END)。本研究旨在确定CS-PFP-10测试及其涉及下肢的功能领域(LBS、BAL或END)与已确立在经股截肢(TFA)患者中使用有效性的测量方法相比的同时效度。10名功能处于K3或更高水平(医疗保险功能分级水平)的TFA患者完成了该研究。参与者接受了CS-PFP-10、截肢者活动能力预测器(AMP)、75米自选步行速度(75米SSWS)测试、下楼梯计时步行(DN楼梯时间)以及稳定性极限(LOS)平衡测试。使用相关分析评估同时效度。AMP、75米SSWS、LOS和DN楼梯时间测试与它们配对的CS-PFP-10领域得分(LBS、BAL或END)以及CS-PFP-10总分高度相关( = ± 0.76至0.86)。这些发现表明,CS-PFP-10的下肢和平衡领域是评估TFA患者身体功能表现的有效指标。