Mountain D C
Department of Biomedical Engineering, Boston University, Massachusetts 02215.
Hear Res. 1989 Sep;41(2-3):101-6. doi: 10.1016/0378-5955(89)90003-8.
The measurement of the low-frequency responses of inner hair cells is complicated by the fact that extracellular cochlear microphonic may be larger than the intracellular inner hair cell potential. A subtraction technique is proposed in which the extracellular and intracellular potentials are recorded sequentially and then subtracted to give an estimate of the true membrane potential. A theoretical analysis is presented which predicts that this calculated inner hair cell membrane potential is a more accurate measure of inner hair cell receptor current than the membrane potential measured with respect to a remote indifferent electrode.