Suppr超能文献

用于股骨转子间骨折固定的拉力螺钉及新型刀片螺钉的尖顶距离测量与移位情况

Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

作者信息

Yang Jesse Chieh-Szu, Chen Hsin-Chang, Lai Yu-Shu, Cheng Cheng-Kung

机构信息

Division of Joint Reconstruction, Department of Orthopaedics, Taipei Veterans General Hospital, Taipei, Taiwan.

Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.

出版信息

PLoS One. 2017 Jan 13;12(1):e0170048. doi: 10.1371/journal.pone.0170048. eCollection 2017.

Abstract

Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw') to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm) before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03). Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12). However, the patient's implanted with a DHS did display significantly greater migration (P<0.001) than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

摘要

除不稳定型和反斜型骨折外,动力髋螺钉(DHS)固定是稳定股骨转子间骨折最常用的方法之一。然而,在骨质疏松患者中经常观察到失败情况,即拉力螺钉有效地从薄弱骨质中“穿出”。新型抗移位刀片已被开发出来,与拉力螺钉联合使用(“刀片螺钉”),以提高骨质疏松性股骨转子间骨折的固定强度。进行了一项体外生物力学研究和一项回顾性临床研究,以评估使用新型刀片螺钉和传统螺纹DHS时拉力螺钉的移位情况。生物力学研究表明,在轻度骨质疏松骨中,刀片螺钉和DHS在达到20000次加载循环之前均出现过度移位(≥10 mm),但刀片螺钉的总体移位明显较少(p≤0.03)。在临床研究中植入刀片螺钉的患者中,3个月随访时螺钉移位无显著差异(P = 0.12)。然而,植入DHS的患者确实比植入刀片螺钉的患者表现出明显更大的移位(P<0.001)。总之,刀片螺钉在动态加载过程中稳定骨碎片,从而为轻度骨质疏松患者的螺钉移位提供显著更大的抵抗力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1482/5234785/c5e91db1d081/pone.0170048.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验