Suppr超能文献

植入物设计的演变降低了初次全膝关节置换术中侧方松解的发生率。

The Evolution of Implant Design Decreases the Incidence of Lateral Release in Primary Total Knee Arthroplasty.

作者信息

Webb Jonathan E, Yang Heidi Y, Collins Jamie E, Losina Elena, Thornhill Thomas S, Katz Jeffrey N

机构信息

Department of Orthopedic Surgery, Orthopaedic and Arthritis Center for Outcomes Research, Brigham and Women's Hospital, Boston, Massachusetts.

Department of Orthopedic Surgery, Orthopaedic and Arthritis Center for Outcomes Research, Brigham and Women's Hospital, Boston, Massachusetts; Division of Rheumatology, Immunology and Allergy, Brigham and Women's Hospital Harvard Medical School, Boston, Massachusetts; Department of Biostatistics, Boston University School of Public Health, Boston, Massachusetts.

出版信息

J Arthroplasty. 2017 May;32(5):1505-1509. doi: 10.1016/j.arth.2016.11.050. Epub 2016 Dec 14.

Abstract

BACKGROUND

Appropriate balancing of the patellofemoral joint (PFJ) using a lateral release can help to prevent patellar instability in total knee arthroplasty (TKA). Contemporary total knee implant designs are characterized by enhanced trochlear geometry more similar to native knee anatomy to minimize instability and reduce utilization of a lateral release.

METHODS

We retrospectively reviewed consecutive TKA cases from a single senior surgeon's practice with 3 successive total knee designs: the Press-Fit Condylar (PFC), the Sigma, and the ATTUNE (DePuy, Warsaw, IN). We evaluated the use of lateral release with each implant type to determine if design changes have improved patellar stability, reducing the need for lateral release. We used multivariate analysis to determine the association between implant type and lateral release, adjusting for age, sex, preoperative alignment, and bearing type.

RESULTS

We evaluated 1991 records of primary TKAs performed from 1980-2015. As compared with the ATTUNE, the adjusted odds of lateral release were greater for patients receiving PFC implants (Odds ratio [OR] 6.35, 95% confidence interval [CI] 3.85,10.49) and Sigma implants (OR 2.02, 95% CI 1.26, 3.23). In addition, fixed bearing implants were associated with greater adjusted odds of lateral release (OR 1.80, 95% CI 1.24, 2.62).

CONCLUSION

We found that older knee implants were associated with higher use of lateral release, with successive designs the need for lateral release to balance the PFJ decreased. Continued design improvements to match the native knee anatomy may further improve the stability of the PFJ in future designs.

摘要

背景

在全膝关节置换术(TKA)中,通过外侧松解对髌股关节(PFJ)进行适当平衡有助于预防髌骨不稳。当代全膝关节植入物设计的特点是滑车几何形状得到增强,更类似于天然膝关节解剖结构,以尽量减少不稳并减少外侧松解的使用。

方法

我们回顾性分析了一位资深外科医生连续使用三种全膝关节设计的TKA病例:压配髁型(PFC)、西格玛(Sigma)和ATTUNE(德普伊公司,印第安纳州华沙)。我们评估了每种植入物类型的外侧松解使用情况,以确定设计变化是否改善了髌骨稳定性,从而减少了外侧松解的需求。我们使用多变量分析来确定植入物类型与外侧松解之间的关联,并对年龄、性别、术前对线和假体类型进行了调整。

结果

我们评估了1980年至2015年期间进行的1991例初次TKA记录。与ATTUNE相比,接受PFC植入物的患者外侧松解的调整后比值比更高(比值比[OR]6.35,95%置信区间[CI]3.85,10.49),接受西格玛植入物的患者也是如此(OR 2.02,95%CI 1.26,3.23)。此外,固定平台假体与外侧松解的调整后比值比更高相关(OR 1.80,95%CI 1.24,2.62)。

结论

我们发现,较旧的膝关节植入物与更高的外侧松解使用率相关,随着设计的不断改进,平衡PFJ所需的外侧松解需求减少。继续改进设计以匹配天然膝关节解剖结构可能会在未来的设计中进一步提高PFJ的稳定性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验