Abstract

BACKGROUND

To determine the sonographic features of peripheral schwannomas.

METHODS

This retrospective study included 54 cases of schwannoma in 51 patients. Ultrasonography (US) and MRI were performed in all patients. The US features of each tumor were analyzed and compared with pathologic findings. The US target sign was compared with the MRI findings.

RESULTS

On US, 53 of the 54 schwannomas had a regular shape and clear margins, and one had an irregular shape. Thirty-seven of the 54 schwannomas were categorized as solid, 16 as cystic and solid, and one as entirely cystic; distal sound enhancement was associated with 47 schwannomas. The target sign was seen in 24, the rat tail sign in 28, the vessel accompanying sign in 22, and the split fat sign in 5. The entering and exiting nerves were situated centrally in 9 and eccentrically in 19 schwannomas. Vascularity on color Doppler imaging using a 0 to III scale was graded 0 in 4 schwannomas, I in 10, II in 26, and III in 14. Twenty-four target signs were detected in 54 schwannomas by US, and 28 were detected by MRI. There was good agreement between the target signs noted on US and those seen on MRI (κ = 0.631, p < 0.001).

CONCLUSIONS

The sonographic diagnosis of peripheral schwannomas is feasible and reliable. The target sign is a prominent US feature in peripheral schwannomas, comparable to that observed with MRI. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:127-133, 2017.

摘要

背景

确定周围神经鞘瘤的超声特征。

方法

本回顾性研究纳入了51例患者的54例神经鞘瘤。所有患者均接受了超声检查(US)和磁共振成像(MRI)。分析每个肿瘤的超声特征并与病理结果进行比较。将超声靶征与MRI结果进行比较。

结果

超声检查显示,54例神经鞘瘤中53例形状规则、边界清晰,1例形状不规则。54例神经鞘瘤中37例为实性,16例为囊实性,1例为完全囊性;47例神经鞘瘤伴有远端声增强。24例可见靶征,28例可见鼠尾征,22例可见血管伴行征,5例可见脂肪分离征。9例神经鞘瘤的出入神经位于中央,19例位于偏心位置。使用0至III级彩色多普勒成像评估血管情况,4例神经鞘瘤为0级,10例为I级,26例为II级,14例为III级。超声在54例神经鞘瘤中检测到24个靶征,MRI检测到28个。超声和MRI观察到的靶征之间具有良好的一致性(κ = 0.631,p < 0.001)。

结论

周围神经鞘瘤的超声诊断可行且可靠。靶征是周围神经鞘瘤突出的超声特征,与MRI所见相当。© 2016威利期刊公司。《临床超声杂志》45:127 - 133,2017年。