机械循环支持对扩张型心肌病(DCM)患者左心室心肌中内皮素受体表达的影响。

Influence of Mechanical Circulatory Support on Endothelin Receptor Expression in Human Left Ventricular Myocardium from Patients with Dilated Cardiomyopathy (DCM).

作者信息

Gärtner Florian, Abraham Getu, Kassner Astrid, Baurichter Daniela, Milting Hendrik

机构信息

Erich & Hanna Klessmann Institute for Cardiovascular Research and Development, Clinic for Thoracic and Cardiovascular Surgery, Heart and Diabetescenter NRW, Bad Oeynhausen, Germany.

Institute of Pharmacology, Pharmacy and Toxicology, University of Leipzig, Leipzig, Germany.

出版信息

PLoS One. 2017 Jan 17;12(1):e0169896. doi: 10.1371/journal.pone.0169896. eCollection 2017.

Abstract

BACKGROUND

In terminal failing hearts ventricular assist devices (VAD) are implanted as a bridge to transplantation. Endothelin receptor (ETR) antagonists are used for treatment of secondary pulmonary hypertension in VAD patients. However, the cardiac ETR regulation in human heart failure and during VAD support is incompletely understood.

METHODS

In paired left ventricular samples of 12 dilated cardiomyopathy patients we investigated the density of endothelin A (ETA) and B (ETB) receptors before VAD implantation and after device removal. Left ventricular samples of 12 non-failing donor hearts served as control. Receptor quantification was performed by binding of [125I]-ET-1 in the presence of nonselective and ETA selective ETR ligands as competitors. Additionally, the ETR mRNA expression was analyzed using quantitative real-time-PCR.

RESULTS

The mRNA of ETA but not ETB receptors was significantly elevated in heart failure, whereas total ETR density analyzed by radioligand binding was significantly reduced due to ETB receptor down regulation. ETA and ETB receptor density showed poor correlation to mRNA data (spearman correlation factor: 0.43 and 0.31, respectively). VAD support had no significant impact on the density of both receptors and on mRNA expression of ETA whereas ETB mRNA increased during VAD. A meta-analysis reveals that the ETA receptor regulation in human heart failure appears to depend on non-failing hearts.

CONCLUSIONS

In deteriorating hearts of patients suffering from dilated cardiomyopathy the ETA receptor density is not changed whereas the ETB receptor is down regulated. The mRNA and the proteins of ETA and ETB show a weak correlation. Non-failing hearts might influence the interpretation of ETA receptor regulation. Mechanical unloading of the failing hearts has no impact on the myocardial ETR density.

摘要

背景

在终末期心力衰竭患者中,植入心室辅助装置(VAD)作为移植的桥梁。内皮素受体(ETR)拮抗剂用于治疗VAD患者的继发性肺动脉高压。然而,人类心力衰竭及VAD支持期间心脏ETR的调节尚不完全清楚。

方法

在12例扩张型心肌病患者的配对左心室样本中,我们研究了VAD植入前和装置移除后的内皮素A(ETA)和B(ETB)受体密度。12例非衰竭供体心脏的左心室样本作为对照。通过在非选择性和ETA选择性ETR配体作为竞争剂存在的情况下,[125I]-ET-1的结合来进行受体定量。此外,使用定量实时PCR分析ETR mRNA表达。

结果

心力衰竭时ETA受体的mRNA显著升高,而ETB受体的mRNA未升高,而通过放射性配体结合分析的总ETR密度因ETB受体下调而显著降低。ETA和ETB受体密度与mRNA数据的相关性较差(斯皮尔曼相关系数分别为0.43和0.31)。VAD支持对两种受体的密度以及ETA的mRNA表达均无显著影响,而ETB mRNA在VAD期间增加。一项荟萃分析表明,人类心力衰竭中ETA受体的调节似乎取决于非衰竭心脏。

结论

在扩张型心肌病患者病情恶化的心脏中,ETA受体密度未改变,而ETB受体下调。ETA和ETB的mRNA与蛋白质显示出弱相关性。非衰竭心脏可能会影响对ETA受体调节的解释。衰竭心脏的机械卸载对心肌ETR密度无影响。