Talanta. 2017 Mar 1;164:677-683. doi: 10.1016/j.talanta.2016.10.103. Epub 2016 Nov 1.
A validated simple, reliable and sensitive adsorptive anodic stripping voltammetric procedure is suggested for the accurate determination of antimony(III) on a glassy carbon electrode (GCE) in the presence of hematoxylin (HT), used as a chemical receptor in antimony analysis for the first time. Under optimized conditions, the plot of stripping peak current versus Sb(III) concentration showed two dynamic linear ranges, 1.0×10 - 0.01µm (R =0.9986) and 0.01 - 1.0µm (R =0.9973) with a detection limit of 9.5×10molL (11.57ngL). The RSD values of intra-day precision and inter-day precision (n =5) for 5.0×10molL Sb(III) were calculated as 1.63% and 2.27%, respectively, indicating that the proposed method has a good precision. Recoveries for Sb(III) in water samples were found to be between 97% and 102% for the 5.0×10molL Sb(III), proving the reliability and accuracy of the method proposed.
提出了一种经过验证的简单、可靠和灵敏的吸附阳极溶出伏安法,用于在存在血根碱(HT)的情况下在玻碳电极(GCE)上准确测定锑(III)。在优化条件下,溶出峰电流与 Sb(III)浓度的关系图显示了两个动态线性范围,1.0×10 - 0.01µm(R = 0.9986)和 0.01 - 1.0µm(R = 0.9973),检测限为 9.5×10 - 7 molL(11.57ngL)。对于 5.0×10 - 7 molL Sb(III),日内精密度和日间精密度(n = 5)的 RSD 值分别计算为 1.63%和 2.27%,表明该方法具有良好的精密度。对于 5.0×10 - 7 molL Sb(III),水样中 Sb(III)的回收率在 97%至 102%之间,证明了所提出方法的可靠性和准确性。