To compare the diagnostic accuracy of PET+MR with PET/CT in the initial staging of head and neck cancer.
Contrast-enhanced PET/CT+MR was performed in 27 patients with newly diagnosed head and neck cancer. PET/CT and PET+MR were evaluated separately, and the TNM stage and factors influencing treatment were assessed.
The TNM staging by PET+MR was comparable to PET/CT (T: p=0.331, N: p=0.453, M: p=0.034). The sensitivity/specificity/accuracy of treatment-influencing factors by PET/CT and PET+MR were 0.68/0.99/0.97, and 1.00/1.00/0.99, respectively.
Whole-body staging with PET+MR yields at least equal diagnostic accuracy as PET/CT in head and neck cancer.