Suppr超能文献

滑动髋螺钉植入物中长疗程双膦酸盐治疗诱发的假体周围股骨应力性骨折:一例独特病例报告

Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report.

作者信息

Adams Mark R, Dunn Conor, Sirkin Michael S, Reilly Mark C

机构信息

Department of Orthopaedics, Rutgers - New Jersey Medical School, Newark, NJ, USA.

出版信息

J Orthop Case Rep. 2016 Sep-Oct;6(4):53-56. doi: 10.13107/jocr.2250-0685.568.

Abstract

INTRODUCTION

Long-term bisphosphonate therapy for osteoporosis is associated with an increased risk of low-to-no energy atypical subtrochanteric and femoral shaft fractures with characteristic radiologic findings. There are few reports of patients with long-term bisphosphonate-induced periprosthetic fractures, all of them had a hip arthroplasty prosthesis. In this report, we present a unique case of a 90-year-old Caucasian female on long-term bisphosphonate therapy with a sliding hip screw implant who sustained a periprosthetic fracture of the femoral shaft at the distal aspect of the plate.

CASE REPORT

In April 2014, a 90-year-old female presented with left thigh pain after a fall from standing height. She had a previous fixation of a left intertrochanteric hip fracture with a sliding hip screw in 1999 and a 9-year history of bisphosphonate therapy. Radiographs obtained in the emergency department revealed a left-sided femoral shaft fracture at the distal aspect of the previously applied five-hole side plate. Of note, the periprosthetic fracture demonstrated cortical thickening at the fracture site of the lateral femoral cortex, lack of comminution as well as a transverse appearance. The patient was taken to the operating room the next day for retrograde placement of an intramedullary nail of the left femur with revision of left intertrochanteric femur fracture fixation. By 3 months postoperatively, she had obtained full radiographic union.

CONCLUSION

This case report highlights the possibility of an atypical fracture distal to the sliding hip screw implant after open reduction internal fixation of an intertrochanteric hip fracture in patients on long-term bisphosphonates.

摘要

引言

骨质疏松症的长期双膦酸盐治疗与低能量至无能量的非典型转子下和股骨干骨折风险增加相关,伴有特征性影像学表现。关于长期双膦酸盐诱导的假体周围骨折患者的报道很少,所有这些患者都有髋关节置换假体。在本报告中,我们介绍了一例独特的病例,一名90岁的白种女性,长期接受双膦酸盐治疗,植入了滑动髋螺钉,在钢板远端发生了股骨干假体周围骨折。

病例报告

2014年4月,一名90岁女性从站立高度跌倒后出现左大腿疼痛。她曾于1999年因左转子间髋部骨折接受滑动髋螺钉固定,并有9年双膦酸盐治疗史。急诊科拍摄的X线片显示,在先前应用的五孔侧板远端发生左侧股骨干骨折。值得注意的是,假体周围骨折在股外侧皮质骨折部位表现为皮质增厚,无粉碎且呈横行外观。患者于次日被送往手术室,行左股骨逆行髓内钉置入术,并对左转子间股骨骨折固定进行翻修。术后3个月,她实现了完全的影像学愈合。

结论

本病例报告强调了长期服用双膦酸盐的患者在转子间髋部骨折切开复位内固定术后,滑动髋螺钉植入物远端发生非典型骨折的可能性。