Suppr超能文献

用于快速定量促甲状腺激素和游离甲状腺素的便携式简易FREND荧光免疫测定法的分析评估

Analytical Evaluation of Portable and Simple FREND Fluorescent Immunoassay for Rapid Quantification of Thyroid-Stimulating Hormone and Free Thyroxine.

作者信息

Park Hye-Sun, Yoo Jaeeun, Lee Hyeyoung, Choi Ae R, Ryu Jihyeong, Park Ki H, Oh Eun-Jee

出版信息

Clin Lab. 2016 Dec 1;62(12):2455-2460. doi: 10.7754/Clin.Lab.2016.160601.

Abstract

BACKGROUND

The FREND™ thyroid stimulating hormone (TSH) and free thyroxine (FT4) assays are newly developed rapid quantitative immunoassays utilizing antibody-conjugated fluorescent nanoparticles in a microfluidic flow system. The FREND system is a simple and portable fluorescence reader with rapid turnaround time (4 - 10 minutes).

METHODS

The analytical sensitivity, precision, and linearity were evaluated. For the method comparison, FREND TSH and FT4 levels were compared with those from ADVIA Centaur XP and Abbott ARCHITECT i2000.

RESULTS

The limit of detection was 0.047 mIU/L and 5.031 pmol/L in FREND TSH and FT4 assays. FREND system had acceptable linearity and precision of  10% across the assay range (0.05 - 25.0 mIU/L for TSH and 1.4 - 96.8 pmol/L for FT4). The functional sensitivity was 0.057 mIU/L for the TSH assay and 4.644 pmol/L for the FT4 assay. Passing-Bablok regression analysis of TSH data showed good correlation among the three assays. For the FT4 assay, FREND FT4 displayed good correlation with the ARCHITECT FT4 assay, but the intercepts and slopes significantly differed between FREND and Centaur results: [FREND FT4] = 4.799 + 0.600 [Centaur FT4].

CONCLUSIONS

The analytical performance of FREND TSH and FT4 assays was satisfactory for use in the clinical laboratory. The FREND FT4 assay was in concordance with ARCHITECT FT4, but it needs further investigation and harmonization.

摘要

背景

FREND™促甲状腺激素(TSH)和游离甲状腺素(FT4)检测是新开发的快速定量免疫检测方法,在微流控流动系统中使用抗体偶联荧光纳米颗粒。FREND系统是一种简单便携的荧光读数仪,周转时间短(4 - 10分钟)。

方法

评估了分析灵敏度、精密度和线性。为进行方法比较,将FREND TSH和FT4水平与ADVIA Centaur XP和雅培ARCHITECT i2000的检测结果进行比较。

结果

FREND TSH和FT4检测的检测限分别为0.047 mIU/L和5.031 pmol/L。FREND系统在整个检测范围内(TSH为0.05 - 25.0 mIU/L,FT4为1.4 - 96.8 pmol/L)具有可接受的线性和≤10%的精密度。TSH检测的功能灵敏度为0.057 mIU/L,FT4检测为4.644 pmol/L。TSH数据的Passing-Bablok回归分析显示三种检测方法之间具有良好的相关性。对于FT4检测,FREND FT4与ARCHITECT FT4检测显示出良好的相关性,但FREND与Centaur结果之间的截距和斜率存在显著差异:[FREND FT4] = 4.799 + 0.600 [Centaur FT4]。

结论

FREND TSH和FT4检测的分析性能在临床实验室使用中令人满意。FREND FT4检测与ARCHITECT FT4检测结果一致,但需要进一步研究和校准。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验