PURPOSE

Surface electromyography (sEMG) using intravaginal probes is of widespread use for assessing pelvic floor muscles (PFM) activity in women. Although considered as a reliable method, its validity has been called into question due to the presence of a phenomenon called crosstalk. Crosstalk is described as the recording of sEMG activity originating from neighboring muscles rather than coming exclusively from the muscles being investigated. The purpose of this review was to provide an overview of existing literature about crosstalk during intravaginal surface electromyographic recordings.

METHODS

A scoping review was performed according to the Arksey and O'Malley framework. An electronic search was conducted on six relevant databases. Additionally, authors were directly contacted to identify grey literature. Data extraction consisted of descriptive numeric analysis as well as thematic analysis, which were conducted by two independent reviewers.

RESULTS

Forty-nine references written by 34 authors coming from 13 different countries constitute the body of evidence of the present review. Eight main themes have been identified through the thematic analysis. The included material varies greatly in terms of methodology, approach to the crosstalk problem and depth of analysis.

CONCLUSIONS

A gap in knowledge affecting the validity of the current sEMG investigation methods was identified. Literature addressing the crosstalk problem is scarce and often flawed. Definitive conclusions are regularly drawn from an insufficient basis of evidence. Further research is, therefore, deeply necessary, although it remains unclear whether this issue can be solved at all with current technology.

摘要

目的

使用阴道内探头的表面肌电图(sEMG)在评估女性盆底肌肉(PFM)活动方面应用广泛。尽管被认为是一种可靠的方法,但其有效性因一种称为串扰的现象而受到质疑。串扰被描述为记录到的sEMG活动源自相邻肌肉,而非仅来自被研究的肌肉。本综述的目的是概述关于阴道内表面肌电图记录期间串扰的现有文献。

方法

根据阿克西和奥马利框架进行了一项范围综述。在六个相关数据库中进行了电子检索。此外,还直接联系了作者以识别灰色文献。数据提取包括描述性数值分析以及主题分析,由两名独立评审员进行。

结果

来自13个不同国家的34位作者撰写的49篇参考文献构成了本综述的证据主体。通过主题分析确定了八个主要主题。所纳入的材料在方法、串扰问题的处理方法和分析深度方面差异很大。

结论

发现了影响当前sEMG研究方法有效性的知识空白。解决串扰问题的文献稀缺且往往存在缺陷。经常在证据不足的基础上得出确定性结论。因此,进一步的研究非常必要,尽管目前尚不清楚这个问题能否用现有技术完全解决。