Abstract

BACKGROUND

In total knee arthroplasty (TKA), femoral component rotation is an important factor in the flexion stability and biomechanics of the patellofemoral joint. However, it remains unclear how much tension is appropriate when performing TKA using the gap technique.

METHODS

One hundred fifty TKAs that used the gap technique were randomized into one of the three groups. Gravity group (n=50) included patients who underwent TKA using only the weight of the patient's lower leg. In 20-lbf group (n=50) and 30-lbf group (n=50), a gap-tensioning device was set at 20lbf and 30lbf respectively. The femoral component rotation was measured based on the clinical transepicondylar axis (cTEA) on postoperative CT and any outliers (a femoral component rotation diverging from the cTEA over 3°) were evaluated.

RESULTS

The mean femoral component rotation was -0.82°±2.44° (95% confidence interval [CI], -1.52° to -0.13°) in gravity group, -0.40°±2.22° (95% CI, -1.03° to 0.23°) in 20-lbf group, and 1.37°±2.70° (95% CI, 0.61° to 2.14°) in 30-lbf group. The mean femoral component rotation in 30-lbf group was significantly different from that in gravity group (p<0.001) and 20-lbf group (p<0.001). There were more outliers in 30-lbf group (18% in gravity group, 18% in 20-lbf group, and 36% in 30-lbf group; p=0.043).

CONCLUSIONS

The use of a tensioning device set at 30lbf resulted in an externally rotated femoral component and frequent outliers.

摘要

背景

在全膝关节置换术(TKA)中,股骨组件旋转是髌股关节屈曲稳定性和生物力学的一个重要因素。然而,使用间隙技术进行TKA时,施加多大的张力才合适仍不清楚。

方法

150例采用间隙技术的TKA患者被随机分为三组。重力组(n = 50)包括仅利用患者小腿重量进行TKA的患者。在20磅力组(n = 50)和30磅力组(n = 50)中,间隙张紧装置分别设置为20磅力和30磅力。根据术后CT上的临床经髁轴(cTEA)测量股骨组件旋转情况,并对任何异常值(股骨组件旋转偏离cTEA超过3°)进行评估。

结果

重力组股骨组件平均旋转角度为-0.82°±2.44°(95%置信区间[CI],-1.52°至-0.13°),20磅力组为-0.40°±2.22°(95%CI,-1.03°至0.23°),30磅力组为1.37°±2.70°(95%CI,0.61°至2.14°)。30磅力组的股骨组件平均旋转角度与重力组(p<0.001)和20磅力组(p<0.001)相比有显著差异。30磅力组的异常值更多(重力组为18%,20磅力组为18%,30磅力组为36%;p = 0.043)。

结论

使用设置为30磅力的张紧装置会导致股骨组件向外旋转且频繁出现异常值。