Vinciguerra Paolo, Camesasca Fabrizio I, Vinciguerra Riccardo, Arba-Mosquera Samuel, Torres Ingrid, Morenghi Emanuela, Randleman J Bradley
J Refract Surg. 2017 Feb 1;33(2):89-95. doi: 10.3928/1081597X-20161122-01.
To compare visual outcomes and postoperative aberrations after surface ablation performed with a 750-Hz versus a 1,050-Hz excimer laser coupled with an ablation software designed to reduce corneal surface irregularity.
Retrospective comparative trial of myopic eyes that had refractive surgery consecutively treated with transepithelial advanced surface ablation with a 750-Hz excimer laser (750 group) versus a 1,050-Hz excimer laser coupled with the Smart Pulse Technology ablation software (SPT group). The SPT algorithm is a laser pulse technology software aimed at reducing surface irregularity of the stromal bed at the end of treatment. The authors evaluated the effect of this smoothing on final visual acuity. Patients were observed for 6 months.
A total of 139 eyes in the 750 group and 40 eyes in the SPT group were evaluated. Epidemiological and preoperative refractive data of the two groups were comparable. Uncorrected distance visual acuity improved with time and was significantly better in the SPT group (-0.04 ± 0.61 logMAR for the SPT group vs 0.02 ± 0.78 logMAR for the 750 group) (P < .001). At 6 months, 55% versus 21% achieved 20/16 or better (P = .005) and 90% versus 65% achieved 20/20 or better (P = .019) visual acuity in the SPT and 750 groups, respectively. Corrected distance visual acuity improved with time and appeared to be influenced by group (P = .054), with better results in the SPT group. Coma and trefoil improved significantly with time in a similar manner in both groups.
Surface ablation with the 1,050-Hz excimer laser and SPT software, aimed at reducing the final superficial stromal irregularity, led to improvement of 6-month uncorrected visual acuity. [J Refract Surg. 2017;33(2):89-95.].
比较使用750赫兹与1050赫兹准分子激光联合旨在减少角膜表面不规则性的消融软件进行表面消融后的视觉效果和术后像差。
对接受屈光手术的近视眼睛进行回顾性比较试验,这些眼睛连续接受经上皮先进表面消融,其中一组使用750赫兹准分子激光(750组),另一组使用1050赫兹准分子激光联合智能脉冲技术消融软件(SPT组)。SPT算法是一种激光脉冲技术软件,旨在减少治疗结束时基质床的表面不规则性。作者评估了这种平滑处理对最终视力的影响。对患者进行了6个月的观察。
750组共评估了139只眼,SPT组共评估了40只眼。两组的流行病学和术前屈光数据具有可比性。未矫正远视力随时间改善,且SPT组明显更好(SPT组为-0.04±0.61 logMAR,750组为0.02±0.78 logMAR)(P<.001)。在6个月时,SPT组和750组分别有55%和21%的患者达到20/16或更好的视力(P=.005),90%和65%的患者达到20/20或更好的视力(P=.019)。矫正远视力随时间改善,且似乎受组别影响(P=.054),SPT组结果更好。两组的彗差和三叶草像差均随时间以相似方式显著改善。
使用1050赫兹准分子激光和SPT软件进行表面消融,旨在减少最终浅层基质不规则性,可改善6个月时的未矫正视力。[《屈光手术杂志》。2017年;33(2):89-95。]