Department of Ophthalmology, Mardin State Hospital, Mardin, Turkey.
Department of Ophthalmology, Faculty of Medicine, Hacettepe University, Ankara, Turkey.
Retina. 2018 Mar;38(3):614-619. doi: 10.1097/IAE.0000000000001557.
To investigate the relationship between choroidal thicknesses (CT), central foveal thicknesses, multifocal electroretinography (mf-ERG) responses, and best-corrected visual acuity levels in patients with Stargardt disease (STGD).
A total of 30 eyes of 30 patients with STGD, and 30 age- and sex-matched healthy controls were included in the study. All participants underwent detailed ophthalmic examination including best-corrected visual acuity and spectral domain optical coherence tomography measurements, and also patients with STGD were performed mf-ERG.
The mean subfoveal CT values were 271.95 ± 85.57 μm in patients with STGD and 355.73 ± 87.41 μm in the control group (P < 0.001). The mean central foveal thickness values were 223.56 ± 61.38 μm in patients with STGD and 272.46 ± 27.52 μm in the control group (P < 0.001). The mean central and paracentral mf-ERG responses (45.71 ± 26.60 and 16.47 ± 10.75 Nv/deg respectively) in patients with STGD were significantly lower from the normal ranges (66.6-130.8 Nv/deg and 30.9-77.7 Nv/deg, respectively; P < 0.001 for both). There was a statistically significant correlation between subfoveal CT and best-corrected visual acuity levels (P = 0.012, r = -0.452), and between parafoveal CT and inner retinal thickness and paracentral mf-ERG responses (P = 0.043, r = +0.372 and P = 0.049, r = +0.363, respectively). Paracentral mf-ERG responses were also correlated with outer retinal thickness values (P = 0.005, r = +0.503).
Patients with STGD have a thinner CT, which may be responsible for some of the clinical findings. The pathophysiological significance of these findings needs further study.
研究斯塔加特病(STGD)患者脉络膜厚度(CT)、中心凹视网膜厚度、多焦视网膜电图(mf-ERG)反应与最佳矫正视力水平之间的关系。
纳入 30 例 30 只眼 STGD 患者和 30 名年龄和性别匹配的健康对照者。所有参与者均接受详细的眼科检查,包括最佳矫正视力和光谱域光学相干断层扫描测量,STGD 患者还进行 mf-ERG 检查。
STGD 患者的平均黄斑下 CT 值为 271.95 ± 85.57 μm,对照组为 355.73 ± 87.41 μm(P<0.001)。STGD 患者的平均中心凹视网膜厚度值为 223.56 ± 61.38 μm,对照组为 272.46 ± 27.52 μm(P<0.001)。STGD 患者的中央和旁中央 mf-ERG 反应(分别为 45.71 ± 26.60 和 16.47 ± 10.75 Nv/deg)明显低于正常范围(分别为 66.6-130.8 Nv/deg 和 30.9-77.7 Nv/deg;均 P<0.001)。黄斑下 CT 与最佳矫正视力水平之间存在统计学显著相关性(P=0.012,r=-0.452),旁黄斑 CT 与内视网膜厚度和旁中央 mf-ERG 反应之间存在统计学显著相关性(P=0.043,r=+0.372 和 P=0.049,r=+0.363)。旁中央 mf-ERG 反应与外视网膜厚度值也呈显著相关性(P=0.005,r=+0.503)。
STGD 患者的 CT 变薄,这可能是一些临床发现的原因。这些发现的病理生理意义需要进一步研究。