Suppr超能文献

基于适配体和磁珠的血管内皮生长因子比色检测方法

[A colorimetric method for vascular endothelial growth factor detection based on aptamer and magnetic beads].

作者信息

Liu Jing-Rong, Pan Yun-Ling, Zhao Yan-Ping, Liu Mei-Cen, Chen Jing-Hua, Li Chun-Yan

机构信息

Department of Oncology with Integrated Traditional Chinese and Western Medicine, First Hospital of Fuzhou, Fuzhou 350009, China. E-mail:

出版信息

Nan Fang Yi Ke Da Xue Xue Bao. 2016 Feb 20;37(2):210-215. doi: 10.3969/j.issn.1673-4254.2017.02.11.

Abstract

OBJECTIVE

To develop a novel colorimetric method for detecting the tumor biomarker vascular endothelial growth factor (VEGF) based on aptamer and magnetic beads.

METHODS

The capture aptamer was hybridized to urease functionalized single-stranded DNA (ssDNA) and immobilize on the surface of magnetic beads by specific biotin-avidin binding. In the presence of VEGF, aptamers bound to VEGF to form a specific stem-loop structure to release the urease functionalized ssDNA. After separation, the supernatant was transferred to a tube and urea and phenol red were added. Urease hydrolyzed urea to produce ammonia to cause an increase of the pH value and a color change of phenol red. The results were inspected with either the naked eyes or by a UV spectrophotometer.

RESULTS

Under optimized conditions, the detection system showed a good linear relationship for VEGF detection in the range of 0.1 to 10 pmol/L with a detection limit as low as 0.06 pmol/L. The results of VEGF detection in the serum of patients with lung cancer were consistent with those using an ELISA Kit. The results of examination of 10 serum samples with this aptamer-based method and ELISA kit showed that the accuracy of this method was 90%.

CONCLUSION

This aptamer-based system provides an simple and convenient method for VEGF detection with a high sensitivity and selectivity.

摘要

目的

基于适配体和磁珠开发一种检测肿瘤生物标志物血管内皮生长因子(VEGF)的新型比色法。

方法

捕获适配体与脲酶功能化的单链DNA(ssDNA)杂交,并通过特异性生物素-抗生物素蛋白结合固定在磁珠表面。在VEGF存在的情况下,适配体与VEGF结合形成特定的茎环结构,从而释放脲酶功能化的ssDNA。分离后,将上清液转移至试管中,加入尿素和酚红。脲酶水解尿素产生氨,导致pH值升高和酚红颜色变化。结果通过肉眼或紫外分光光度计检测。

结果

在优化条件下,该检测系统对VEGF的检测在0.1至10 pmol/L范围内呈现良好的线性关系,检测限低至0.06 pmol/L。肺癌患者血清中VEGF的检测结果与使用ELISA试剂盒的结果一致。用这种基于适配体的方法和ELISA试剂盒检测10份血清样本的结果表明,该方法的准确率为90%。

结论

这种基于适配体的系统为VEGF检测提供了一种简单方便的方法,具有高灵敏度和选择性。