Moore Kelly E, Benoit Julia S, Berntsen David A
*OD, MS †PhD ‡OD, PhD, FAAO The Ocular Surface Institute, College of Optometry (KEM, DAB), and College of Optometry & Texas Institute for Measurement, Evaluation, and Statistics (TIMES) (JSB), University of Houston, Houston, Texas.
Optom Vis Sci. 2017 Mar;94(3):370-379. doi: 10.1097/OPX.0000000000001053.
Peripheral retinal defocus has been implicated in myopia progression. The effect of commercially available spherical soft contact lenses (SCLs) on peripheral defocus of adult myopic eyes was investigated.
Twenty-five young adults with spherical equivalent (SE) refractions between -0.50D and -6.00D were enrolled. Cycloplegic autorefraction (right eye) was measured centrally and ±20°, ±30°, and ±40° from the line of sight along the horizontal meridian using an autorefractor. Four commercially available spherical SCLs (Biofinity, Acuvue2, PureVision2, and Air Optix Night & Day Aqua) were evaluated. SE defocus (M) was used to calculate relative peripheral defocus (RPD) while wearing each SCL and relative peripheral refraction of the uncorrected eye. Spherical aberration (SA) changes caused by each SCL were measured along the line of sight by aberrometry. Peripheral defocus was analyzed using repeated-measures analyses of variance (RM-ANOVA). The association between changes in axial SA and the change in peripheral defocus was evaluated using linear mixed models.
The mean age (±SD) and central SE refractive error were 24.0 ± 1.3 years and -3.45 ± 1.42D, respectively. PureVision2 did not change RPD (P = .33). Significant myopic shifts on the temporal retina were found with three lenses: Acuvue 2 (-0.29D at 30°; -0.80D at 40°; both P ≤ .01), Biofinity (-1.21 D at 40°; P = .02), and Air Optix Night & Day Aqua (-0.23D at 20°, -0.48D at 30°, and -1.50D at 40°; all P < .004). All SCLs caused a negative change in SA. SCLs inducing less negative (more positive) SA changes were associated with a less hyperopic change in RPD.
Spherical SCL design can influence the peripheral defocus profile experienced by a myopic eye. Several, but not all, SCLs reduced peripheral hyperopia. Differences in how SCL types influence peripheral defocus may have implications for myopia progression.
周边视网膜离焦与近视进展有关。本研究调查了市售球面软性接触镜(SCL)对成年近视眼周边离焦的影响。
招募了25名等效球镜度(SE)在-0.50D至-6.00D之间的年轻成年人。使用自动验光仪在中央以及沿水平子午线视线±20°、±30°和±40°处测量(右眼)睫状肌麻痹下的自动验光结果。评估了四种市售球面SCL(Biofinity、Acuvue2、PureVision2和Air Optix Night & Day Aqua)。佩戴每种SCL时,使用SE离焦(M)计算相对周边离焦(RPD)以及未矫正眼的相对周边屈光。通过像差仪沿视线测量每种SCL引起的球差(SA)变化。使用重复测量方差分析(RM-ANOVA)分析周边离焦。使用线性混合模型评估轴向SA变化与周边离焦变化之间的关联。
平均年龄(±标准差)和中央SE屈光不正分别为24.0±1.3岁和-3.45±1.42D。PureVision2未改变RPD(P = 0.33)。发现三种镜片使颞侧视网膜出现显著近视性偏移:Acuvue 2(30°处为-0.29D;40°处为-0.80D;均P≤0.01)、Biofinity(40°处为-1.21D;P = 0.02)和Air Optix Night & Day Aqua(20°处为-0.23D,30°处为-0.48D,40°处为-1.50D;均P < 0.004)。所有SCL均导致SA出现负向变化。SA变化为负性较小(正性较大)的SCL与RPD的远视性变化较小相关。
球面SCL设计可影响近视眼所经历的周边离焦情况。几种(但并非全部)SCL可减少周边远视。不同类型SCL影响周边离焦的方式差异可能对近视进展有影响。