Department of Neurosurgery, University of Illinois at Chicago, Chicago, Illinois, USA.
Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA.
J Neurointerv Surg. 2018 Feb;10(2):156-161. doi: 10.1136/neurintsurg-2017-012991. Epub 2017 Feb 24.
The hemodynamic evaluation of cerebral arteriovenous malformations (AVMs) using DSA has not been validated against true flow measurements.
To validate AVM hemodynamics assessed by DSA using quantitative magnetic resonance angiography (QMRA).
Patients seen at our institution between 2007 and 2016 with a supratentorial AVM and DSA and QMRA obtained before any treatment were retrospectively reviewed. DSA assessment of AVM flow comprised AVM arterial-to-venous time (A-Vt) and iFlow transit time. A-Vt was defined as the difference between peak contrast intensity in the cavernous internal carotid artery and peak contrast intensity in the draining vein. iFlow transit times were determined using syngo iFlow software. A-Vt and iFlow transit times were correlated with total AVM flow measured using QMRA and AVM angioarchitectural and clinical features.
33 patients (mean age 33 years) were included. Nine patients presented with hemorrhage. Mean AVM volume was 9.8 mL (range 0.3-57.7 mL). Both A-Vt (r=-0.47, p=0.01) and iFlow (r=-0.44, p=0.01) correlated significantly with total AVM flow. iFlow transit time was significantly shorter in patients who presented with seizure but A-Vt and iFlow did not vary with other AVM angioarchitectural features such as venous stenosis or hemorrhagic presentation.
A-Vt and iFlow transit times on DSA correlate with cerebral AVM flow measured using QMRA. Thus, these parameters may be used to indirectly estimate AVM flow before and after embolization during angiography in real time.
DSA 对脑动静脉畸形(AVM)的血流动力学评估尚未通过真实流量测量进行验证。
使用定量磁共振血管造影(QMRA)验证 DSA 评估的 AVM 血流动力学。
回顾性分析了 2007 年至 2016 年间在我院就诊的 33 例幕上 AVM 患者,这些患者均进行了 DSA 和 QMRA 检查,且在任何治疗之前都获得了这些检查结果。AVM 血流的 DSA 评估包括 AVM 动脉到静脉时间(A-Vt)和 iFlow 渡越时间。A-Vt 定义为海绵窦内颈动脉峰值对比度与引流静脉峰值对比度之间的差异。iFlow 渡越时间通过 syngo iFlow 软件确定。使用 QMRA 和 AVM 血管造影特征及临床特征,将 A-Vt 和 iFlow 渡越时间与总 AVM 流量进行相关性分析。
33 例患者(平均年龄 33 岁)纳入研究。9 例患者有出血表现。AVM 体积平均为 9.8mL(范围 0.3-57.7mL)。A-Vt(r=-0.47,p=0.01)和 iFlow(r=-0.44,p=0.01)与总 AVM 流量显著相关。iFlow 渡越时间在癫痫发作患者中显著缩短,但 A-Vt 和 iFlow 并不随静脉狭窄或出血等其他 AVM 血管造影特征而变化。
DSA 上的 A-Vt 和 iFlow 渡越时间与使用 QMRA 测量的脑 AVM 流量相关。因此,这些参数可用于实时在血管造影过程中栓塞前后间接估计 AVM 流量。