Suppr超能文献

三种不同袢设计的单片丙烯酸酯人工晶状体植入后前囊稳定性的比较

Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design.

作者信息

Yang Soonwon, Lim Sung A, Na Kyung-Sun, Joo Choun-Ki

机构信息

Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.

Nune Eye Hospital, Seoul, Korea.

出版信息

Korean J Ophthalmol. 2017 Feb;31(1):32-38. doi: 10.3341/kjo.2017.31.1.32. Epub 2017 Feb 2.

Abstract

PURPOSE

To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability.

METHODS

One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic IOL (n = 97), or a plate-haptic IOL (n = 89). The area of the anterior capsule opening, IOL decentration, and capsule overlap were measured using retroillumination photospot 1 day and 2 months after cataract surgery.

RESULTS

The area of capsule opening at postoperative day 1 was significantly different between the three IOLs ( < 0.01). All IOLs showed reduction of the anterior capsule opening from 1 day to 2 months after surgery, and greater reduction was shown in the modified C-haptic IOL ( < 0.001). At postoperative month 2, IOL decentration was significantly different between the IOLs and showed a positive correlation with the mean area reduction during month 2.

CONCLUSIONS

The degree of anterior capsule contraction and IOL decentration in modified L-haptic IOLs were less than those in modified C-haptic IOLs and comparable to those in plate-haptic IOLs.

摘要

目的

比较三种类型人工晶状体(IOL)的前囊收缩和人工晶状体偏心情况,以确定襻设计对前囊稳定性的影响。

方法

150例患者纳入这项前瞻性随机研究,260只眼植入以下一种人工晶状体:改良L襻人工晶状体(n = 74)、改良C襻人工晶状体(n = 97)或平板襻人工晶状体(n = 89)。在白内障手术后1天和2个月,使用后照光光斑测量前囊开口面积、人工晶状体偏心和囊重叠情况。

结果

三种人工晶状体术后第1天的囊开口面积有显著差异(<0.01)。所有人工晶状体在术后1天至2个月均显示前囊开口减小,改良C襻人工晶状体减小更明显(<0.001)。术后第2个月,人工晶状体偏心在不同人工晶状体之间有显著差异,且与第2个月的平均面积减小呈正相关。

结论

改良L襻人工晶状体的前囊收缩程度和人工晶状体偏心程度小于改良C襻人工晶状体,与平板襻人工晶状体相当。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9c71/5327172/d7820767deeb/kjo-31-32-g001.jpg

相似文献

2
Intraocular lens factors that may affect anterior capsule contraction.
Ophthalmology. 2005 Feb;112(2):286-92. doi: 10.1016/j.ophtha.2004.11.013.
3
Anterior capsule opacification: correlation of pathologic findings with clinical sequelae.
Ophthalmology. 2001 Sep;108(9):1675-81. doi: 10.1016/s0161-6420(01)00674-1.
4
Intraocular lens tilt and decentration in secondary ciliary sulcus implantation in paediatric eyes: A 3-year prospective study.
Acta Ophthalmol. 2024 Aug;102(5):e805-e812. doi: 10.1111/aos.16643. Epub 2024 Jan 31.
7
Clinical performance of Alcon SA30AL and SA60AT single-piece acrylic intraocular lenses.
J Cataract Refract Surg. 2002 Jul;28(7):1112-23. doi: 10.1016/s0886-3350(02)01386-x.
10
Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule.
J Cataract Refract Surg. 2005 Feb;31(2):337-42. doi: 10.1016/j.jcrs.2004.06.042.

引用本文的文献

1
Effect of intraocular lens material and haptic design on anterior capsule contraction after cataract surgery: A systematic review and meta-analysis.
Graefes Arch Clin Exp Ophthalmol. 2024 May;262(5):1421-1432. doi: 10.1007/s00417-023-06230-x. Epub 2023 Oct 13.
2
Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.
Cochrane Database Syst Rev. 2021 Aug 16;8(8):CD012516. doi: 10.1002/14651858.CD012516.pub2.
3
Circular YAG laser anterior capsulotomy for anterior capsule contraction syndrome.
Int Ophthalmol. 2019 Nov;39(11):2497-2503. doi: 10.1007/s10792-019-01094-9. Epub 2019 Mar 11.

本文引用的文献

1
Rapid anterior capsular contraction after phacoemulsification surgery in a patient with retinitis pigmentosa.
Clin Ophthalmol. 2013;7:839-42. doi: 10.2147/OPTH.S42122. Epub 2013 May 6.
2
Anterior capsule contraction and flare intensity in the early stages after cataract surgery in eyes with diabetic retinopathy.
J Cataract Refract Surg. 2013 May;39(5):716-21. doi: 10.1016/j.jcrs.2012.12.029. Epub 2013 Mar 28.
3
Effect of haptic material and number of intraocular lens on anterior capsule contraction after cataract surgery.
Korean J Ophthalmol. 2013 Feb;27(1):7-11. doi: 10.3341/kjo.2013.27.1.7. Epub 2013 Jan 15.
4
Comparison of anterior capsule contraction between hydrophobic and hydrophilic intraocular lens models.
Graefes Arch Clin Exp Ophthalmol. 2010 Aug;248(8):1155-8. doi: 10.1007/s00417-010-1373-2. Epub 2010 Apr 23.
6
Effect of the hydrophilicity of acrylic intraocular lens material and haptic angulation on anterior capsule opacification.
Br J Ophthalmol. 2007 Apr;91(4):476-80. doi: 10.1136/bjo.2006.103390. Epub 2006 Nov 15.
7
Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule.
J Cataract Refract Surg. 2005 Feb;31(2):337-42. doi: 10.1016/j.jcrs.2004.06.042.
8
Comparison of the biomechanical behavior of foldable intraocular lenses.
J Cataract Refract Surg. 2004 Nov;30(11):2397-402. doi: 10.1016/j.jcrs.2004.03.041.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验