Wang S-Y, Gao W, Zhong Y-M, Sun A-M, Wang Q, Hu L-W, Qiu H-S, Li J-Y
Diagnostic Imaging Center, Shanghai Children's Medical Center Affiliated with Shanghai Jiao Tong University Medical School, No. 1678 Dong Fang Road, Shanghai 200127, PR China.
Department of Cardiology, Shanghai Children's Medical Center Affiliated with Shanghai Jiao Tong University Medical School, No. 1678 Dong Fang Road, Shanghai 200127, PR China.
Clin Radiol. 2017 Jun;72(6):502-507. doi: 10.1016/j.crad.2017.01.017. Epub 2017 Mar 6.
To demonstrate the clinical value of prospective electrocardiography (ECG)-triggered cardiac computed tomography (CT) with low concentration contrast medium, low tube voltage, and adaptive statistic iterative reconstruction (ASIR) to reduce both radiation and contrast dose in examining infants with complex congenital heart disease (CHD).
Forty-four consecutive infants (19 male, 25 female, age: 8.06±4.33 months, weight: 7.31±1.36 kg) with complex CHD underwent prospective ECG-triggered low-dose cardiac CT using 80 kVp and 120 mA. The contrast agent was iodixanol (270 mg iodine/ml, Visipaque, GE Healthcare, Co. Cork, Ireland). Cardiac CT images were reconstructed with 70% ASIR. The quantitative CT image quality was assessed by image noise in adipose tissue and contrast-to-noise ratio (CNR) in the aorta. The qualitative image analysis was performed on a five-point grading scale by two independent reviewers and interobserver variability was calculated. The results of 32 CT examinations were also compared with the available surgical results for diagnostic accuracy evaluation.
The effective dose was 0.55±0.10 mSv for the patient population. The iodine load was 3.95±0.73 g iodine. Image noise in adipose tissue was 16.24±1.42 HU and CNR in aorta was 21.90±7.10. All images were acceptable for diagnosis with an average score of 4.52±0.38 and good agreement between reviewers (kappa=0.75). Compared to the surgery results in 32 cases, CT was 97% and 88% accurate diagnosing extracardiac and intracardiac defects, respectively.
Prospective ECG-triggered cardiac CT using 80 kVp, low-concentration iodinated contrast agent (270 mg iodine/ml) and 70% ASIR reconstruction provides excellent image quality and accurate diagnosis for complex congenital heart disease in infants with reduced contrast medium dose and low radiation dose.
证明前瞻性心电图(ECG)触发的心脏计算机断层扫描(CT)结合低浓度造影剂、低管电压和自适应统计迭代重建(ASIR)在检查复杂先天性心脏病(CHD)婴儿时降低辐射和造影剂剂量的临床价值。
44例连续的复杂CHD婴儿(男19例,女25例,年龄:8.06±4.33个月,体重:7.31±1.36 kg)接受了前瞻性ECG触发的低剂量心脏CT检查,管电压80 kVp,电流120 mA。造影剂为碘克沙醇(270 mg碘/ml,威视派克,通用电气医疗集团,爱尔兰科克公司)。心脏CT图像采用70% ASIR重建。通过脂肪组织中的图像噪声和主动脉中的对比噪声比(CNR)评估定量CT图像质量。由两名独立的阅片者采用五点分级量表进行定性图像分析,并计算观察者间的变异性。还将32例CT检查结果与现有的手术结果进行比较,以评估诊断准确性。
该患者群体的有效剂量为0.55±0.10 mSv。碘负荷为3.95±0.73 g碘。脂肪组织中的图像噪声为16.24±1.42 HU,主动脉中的CNR为21.90±7.10。所有图像均可用于诊断,平均评分为4.52±0.38,阅片者之间一致性良好(kappa = 0.75)。与32例手术结果相比,CT诊断心外和心内缺陷的准确率分别为97%和88%。
采用80 kVp、低浓度碘化造影剂(270 mg碘/ml)和70% ASIR重建的前瞻性ECG触发心脏CT可为复杂先天性心脏病婴儿提供优质的图像质量和准确的诊断,同时降低造影剂剂量和辐射剂量。