Int J Cardiovasc Imaging. 2022 Feb;38(2):413-422. doi: 10.1007/s10554-021-02390-1. Epub 2021 Sep 6.
The purpose of this study is to evaluate the radiation dose, image quality, and diagnostic accuracy of prospective ECG-gated cardiac CT at 70 kV and adaptive statistical iterative reconstruction (ASIR), with a single source, 512 slice MDCT in the diagnosis of complex congenital heart disease in infants. We retrospectively evaluated 47 infants (ages 1 day to 353 days) with prospective ECG-gated cardiac CT that was performed on a single source 512 slice CT at low tube voltage (70 kV) using a wide detector aperture, adaptive statistical iterative reconstruction algorithm (ASIR), and specific reconstruction software reducing coronary motion artifacts (SnapShot Freeze). All cardiac images were obtained during the first pass of contrast material through the anatomic structures of interest and the targets for the center of the acquisition window were set 45% of the R-R interval during one cardiac cycle without sedation and breath-hold. The median effective dose measured in our study was 0.64 ± 0.16 mSv. The average subjective overall image quality score was 4.34 ± 0.31 (range 3-5). For the determination of objective image quality, Mean Noise (HU), SNR, and CNR values emerged as 20.8, 28.7(for pulmonary artery), and 27.1, respectively. Diagnostic accuracy was 100% for the main purposes for the main clinical indication. During cardiac CT examination, pathologies in addition to cardiac anomalies were found in 9/47 of cases (7 severe airway obstructions,1 posterior diaphragmatic hernia, 1 vertebral anomaly). Prospective ECG-gated cardiac CT scan at 70 kV and ASIR in infants with complex CHD provides low radiation dose (submillisievert) in a single heartbeat with a good objective and subjective image quality. It also provides important benefits in the diagnosis of additional pathology.
本研究旨在评估在诊断复杂先天性心脏病(CHD)中,使用单源 512 层 MDCT 以 70kV 管电压、自适应统计迭代重建(ASIR)和特定的减少冠状动脉运动伪影的重建软件(SnapShot Freeze)进行前瞻性心电门控心脏 CT 的辐射剂量、图像质量和诊断准确性。我们回顾性评估了 47 例婴儿(1 天至 353 天)的前瞻性心电门控心脏 CT 检查,这些婴儿均在单源 512 层 CT 上进行,管电压低(70kV),使用宽探测器孔径、自适应统计迭代重建算法(ASIR)和特定的减少冠状动脉运动伪影的重建软件(SnapShot Freeze)。所有心脏图像均在对比剂首次通过感兴趣的解剖结构期间获得,采集窗中心的目标设定在一个心动周期的 45%的 R-R 间隔,无需镇静和屏气。我们研究中的平均有效剂量为 0.64±0.16mSv。平均主观整体图像质量评分为 4.34±0.31(范围 3-5)。对于客观图像质量的确定,平均噪声(HU)、SNR 和 CNR 值分别为 20.8、28.7(肺动脉)和 27.1。主要临床适应证的主要目的诊断准确性为 100%。在心脏 CT 检查期间,除了心脏异常外,还在 47 例中的 9 例(7 例严重气道阻塞、1 例后膈疝、1 例脊柱异常)发现了其他病变。在复杂 CHD 婴儿中,以 70kV 和 ASIR 进行前瞻性心电门控心脏 CT 扫描,可在单次心跳中提供低辐射剂量(毫希沃特),具有良好的客观和主观图像质量。它还为诊断额外的病变提供了重要的益处。