Suppr超能文献

[Evaluation of a new immunochromatographic kit for enhanced detection of influenza B virus].

作者信息

Ashikawa Yasushi, Takasaki Yoshio, Shindo Shizuo, Yamashita Yuji, Shibao Keigo, Yokoyama Takashi, Yokoyama Takato, Iwaya Minako, Kiyomatsu Yumi, Miyamoto Hiroshi

机构信息

Division of Microbiology, Department of Pathology and Microbiology, Faculty of Medicine, Saga University.

Takasaki Pediatric Clinic.

出版信息

Rinsho Biseibutshu Jinsoku Shindan Kenkyukai Shi. 2017 Mar 22;27(1):25-31.

Abstract

We have evaluated a new immunochromatographic kit, "KBM LineCheck Flu AB", which had been developed for enhanced detection of influenza B viruses. Five strains of influenza A and B viruses were tested for reactivity and detection limits of the kit. Compared with the detection limits of commercially available kit of QuickNavi-Flu, "KBM LineCheck Flu AB" showed a nearly equal reactivity to influenza A viruses, but quadruple reactivity to 2 influenza B viruses. Also, "KBM LineCheck Flu AB" exhibited high specificity when tested in 130 influenza-negative culture specimens derived from 24 adult volunteers. Furthermore, "KBM LineCheck Flu AB" was clinically evaluated by using 866 specimens, including 190 nasal swabs, 201 nasal aspirations, 262 self-blown nasal discharges, and 213 pharyngeal swabs. Compared with the results of QuickNavi-Flu for influenza A, the test efficiency for the nasal swabs, the nasal aspirations, self-blown nasal discharges, and pharyngeal swabs were calculated to be 95.8%, 92.0%, 95.0%, and 94.8%, respectively. Whereas, as to influenza B, the test efficiency for the nasal swabs, the nasal aspirations, self-blown nasal discharges, and pharyngeal swabs was calculated to be 96.3%, 98.5%, 96.2%, and 93.4%, respectively. Similarly, compared with the results of influenza A viral culture, the test efficiency for the nasal swabs, the nasal aspirations, self-blown nasal discharges, and pharyngeal swabs was calculated to be 95.3%, 91.0%, 93.9%, and 92.5%, respectively. Regarding influenza B culture, the test efficiency for the nasal swabs, the nasal aspirations, self-blown nasal discharges, and pharyngeal swabs were calculated to be 95.8%, 97.5%, 95.1%, 91.5%, respectively. Overall, we concluded that the "KBM LineCheck Flu AB" is useful and suitable for diagnosis of influenza A and especially influenza B.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验