Suppr超能文献

正常血液氧亲和力的变异性:一种自动测量方法。

Variability of oxygen affinity of normal blood: an automated method of measurement.

作者信息

Winslow R M, Morrissey J M, Berger R L, Smith P D, Gibson C C

出版信息

J Appl Physiol Respir Environ Exerc Physiol. 1978 Aug;45(2):289-97. doi: 10.1152/jappl.1978.45.2.289.

Abstract

Oxygen equilibrium curves of 48 healthy adult subjects have been measured by the method of Rossi-Bernardi et al. (Clin. Chem. 21: 1747, 1975), in which H2O2 is gradually added to a sample of deoxygenated blood that contains an excess of catalase. The mean P50 for nonsmokers was 26.9 Torr and the distribution of values was slightly skewed to the right (range 24.2--29.9 Torr). The method differs from others previously available in that pH, PCO2, and HCO3-- are constant during oxygenation. The system for control of the experiment and data collection and processing has been automated by the use of a microprocessor so that the equilibrium curve can be obtained quickly, reproducibly, and relatively simply. With the aid of a digital computer, the parameters of the generalized Adair equation can also be estimated.

摘要

采用罗西 - 贝尔纳迪等人(《临床化学》21: 1747, 1975)的方法,对48名健康成年受试者的氧平衡曲线进行了测量。该方法是向含有过量过氧化氢酶的脱氧血液样本中逐渐添加过氧化氢。非吸烟者的平均P50为26.9托,数值分布略向右偏(范围为24.2 - 29.9托)。该方法与之前的其他方法不同之处在于,在氧合过程中pH、PCO2和HCO3-是恒定的。通过使用微处理器,实验控制以及数据收集和处理系统已实现自动化,从而能够快速、可重复且相对简单地获得平衡曲线。借助数字计算机,还可以估计广义阿代尔方程的参数。