Suppr超能文献

同侧肩胛皮瓣锚定系统:用于身体驱动上肢假肢吊带的一种替代方案。

Ipsilateral Scapular Cutaneous Anchor System: An alternative for the harness in body-powered upper-limb prostheses.

作者信息

Hichert Mona, Plettenburg Dick H

机构信息

Faculty Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands.

出版信息

Prosthet Orthot Int. 2018 Feb;42(1):101-106. doi: 10.1177/0309364617691624. Epub 2017 Mar 20.

Abstract

BACKGROUND

Body-powered prosthesis users frequently complain about the poor cosmesis and comfort of the traditional shoulder harness. The Ipsilateral Scapular Cutaneous Anchor System offers an alternative, but it remains unclear to what extent it affects the perception and control of cable operation forces compared to the traditional shoulder harness.

OBJECTIVE

To compare cable force perception and control with the figure-of-nine harness versus the Ipsilateral Scapular Cutaneous Anchor System and to investigate force perception and control at different force levels.

STUDY DESIGN

Experimental trial.

METHODS

Ten male able-bodied subjects completed a cable force reproduction task at four force levels in the range of 10-40 N using the figure-of-nine harness and the Anchor System. Perception and control of cable operating forces were quantified by the force reproduction error and the force variability.

RESULTS

In terms of force reproduction error and force variability, the subjects did not behave differently when using the two systems. The smallest force reproduction error and force variability were found at the smallest target force level of 10 N.

CONCLUSION

The Anchor System performs no differently than the traditional figure-of-nine harness in terms of force perception and control, making it a viable alternative. Furthermore, users perceive and control low operation forces better than high forces. Clinical relevance The Ipsilateral Scapular Cutaneous Anchor System offers an alternative for the traditional harness in terms of cable operation force perception and control and should therefore be considered for clinical use. Low cable operation forces increase the perception and control abilities of users.

摘要

背景

身体驱动假肢使用者经常抱怨传统肩带的美观性和舒适性较差。同侧肩胛皮肤锚定系统提供了一种替代方案,但与传统肩带相比,它在多大程度上影响对缆索操作力的感知和控制仍不清楚。

目的

比较“8”字带与同侧肩胛皮肤锚定系统对缆索力的感知和控制,并研究不同力水平下的力感知和控制情况。

研究设计

实验性试验。

方法

10名男性健康受试者使用“8”字带和锚定系统,在10 - 40牛的四个力水平上完成缆索力再现任务。通过力再现误差和力变异性对缆索操作力的感知和控制进行量化。

结果

在力再现误差和力变异性方面,受试者使用两种系统时的表现没有差异。在10牛的最小目标力水平下,力再现误差和力变异性最小。

结论

在力感知和控制方面,锚定系统的表现与传统“8”字带没有差异,使其成为一种可行的替代方案。此外,使用者对低操作力的感知和控制优于高操作力。临床相关性 同侧肩胛皮肤锚定系统在缆索操作力感知和控制方面为传统肩带提供了一种替代方案,因此应考虑用于临床。低缆索操作力可提高使用者的感知和控制能力。