Abstract

Voriconazole is a triazole broad-spectrum antifungal medication often used to treat fungal infections caused by Aspergillus and Fusarium species. One of the main challenges associated with the implementation of this medication is its narrow therapeutic concentration range, demonstrating toxicity at concentrations above 6μg/mL and limited efficacy at concentrations below 2μg/mL. As a result, methodologies which permit the rapid and accurate quantitation of voriconazole in patients are highly desirable. In this work two different approaches based on coated blade spray directly coupled to mass spectrometry (CBS-MS) are introduced; each enabling the quantitation of voriconazole in plasma samples with a simple and fast sample preparation and no chromatographic step. The first approach involves a rapid extraction (1min) of the target analyte from 300μL of human plasma using conventional laboratory vessels (e.g. vial, 96-well plate). Alternatively, the second strategy consists of a 2min extraction from a plasma droplet (10μL) placed on the coated area of the blade. Both procedures were successfully validated and good linearity (R≥0.998), accuracy (91-122%) and precision (<8%) were attained in the concentration range evaluated (0.1-50μg/mL). Moreover, very good results in terms of relative matrix effects were obtained given that the slopes of the calibration curves constructed in five different plasma lots exhibited relative standard deviation (RSD) values below 7%. Herein we demonstrated that CBS-MS is a technology suitable for the ultra-fast determination of voriconazole in human plasma samples. Indeed, the proposed methodology can be easily used either for routine drug monitoring or for in vitro pharmacokinetic studies in applications where very small sample volumes are available and great temporal resolution is needed.

摘要

伏立康唑是一种三唑类广谱抗真菌药物,常用于治疗由曲霉菌和镰刀菌属引起的真菌感染。使用这种药物的主要挑战之一是其治疗浓度范围狭窄,浓度高于6μg/mL时显示出毒性,而浓度低于2μg/mL时疗效有限。因此,非常需要能够快速、准确地定量患者体内伏立康唑的方法。在这项工作中,介绍了两种基于涂层刀片喷雾直接与质谱联用(CBS-MS)的不同方法;每种方法都能通过简单快速的样品制备且无需色谱步骤来定量血浆样品中的伏立康唑。第一种方法涉及使用常规实验室容器(如小瓶、96孔板)从300μL人血浆中快速提取(1分钟)目标分析物。或者,第二种策略是从放置在刀片涂层区域的血浆液滴(10μL)中提取2分钟。两种方法均成功验证,在所评估的浓度范围(0.1 - 50μg/mL)内获得了良好的线性(R≥0.998)、准确度(91 - 122%)和精密度(<8%)。此外,鉴于在五个不同血浆批次中构建的校准曲线斜率的相对标准偏差(RSD)值低于7%,在相对基质效应方面也获得了非常好的结果。在此,我们证明了CBS-MS是一种适用于超快速测定人血浆样品中伏立康唑的技术。实际上,所提出的方法可轻松用于常规药物监测或体外药代动力学研究,适用于样品体积非常小且需要高时间分辨率的应用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验