Suppr超能文献

采用自动在线预富集和火焰原子荧光光谱法现场测定河口和沿海水域中的痕量溶解锰。

In-field determination of trace dissolved manganese in estuarine and coastal waters with automatic on-line preconcentration and flame atomic fluorescence spectrometry.

作者信息

Feng Sichao, Yuan Dongxing, Huang Yongming, Lin Kunning, Zhou Tingjin

机构信息

State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen, 361102, China.

State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen, 361102, China.

出版信息

Anal Chim Acta. 2017 Apr 22;963:53-60. doi: 10.1016/j.aca.2017.02.030. Epub 2017 Mar 6.

Abstract

An automatic on-line preconcentration and detection system for analysis of trace dissolved manganese (Mn) in estuarine and coastal waters was established, using preconcentration with IDA chelating resin and detection with flame atomic fluorescence spectrometer (FAFS). The rinse (pre-eluent) solution was optimized, for removing the interference ions while retaining the target element. It was found that the interference ions affected the chelating efficiency of Mn, causing variation of the detection blank and sensitivity. This effect varied when sample volume presented as preconcentration time changed. The influence at preconcentration times of 120 s, 30 s and 10 s were carefully investigated and reported. Ten folds of the foreign trace metals Zn, Cu, Ni, Fe, and Al did not show obvious interference on Mn preconcentration and detection. The method detection limit was 0.9 nmol L (n = 7, preconcentration time 120 s). The linear detection range could be adjusted with designed preconcentration time. In addition to high precision and accuracy, the proposed analytical system had the advantages of high integration, and required normal site preparation, low energy supply and simple auxiliary equipment, which was appropriate for in-field operation. Compared with other common in-field applied molecular spectrometry instruments, the inherent high selectivity and multi-element applicability of FAFS highlighted the superiority and potential of the proposed analytical system. It was successfully applied to in-field vehicle-board determination of dissolved Mn in coastal waters around Xiamen, Fujian, China, and it was also used to analyze natural water samples collected from the Jiulongjiang Estuary, Fujian, China.

摘要

建立了一种用于分析河口和沿海水体中痕量溶解锰(Mn)的自动在线预浓缩和检测系统,该系统采用IDA螯合树脂进行预浓缩,并用火焰原子荧光光谱仪(FAFS)进行检测。对冲洗(预洗脱)溶液进行了优化,以去除干扰离子同时保留目标元素。发现干扰离子会影响Mn的螯合效率,导致检测空白和灵敏度发生变化。当进样体积以预浓缩时间表示时,这种影响会有所不同。仔细研究并报告了预浓缩时间为120 s、30 s和10 s时的影响。痕量的Zn、Cu、Ni、Fe和Al等外来金属的十倍量对Mn的预浓缩和检测未显示明显干扰。方法检出限为0.9 nmol/L(n = 7,预浓缩时间120 s)。线性检测范围可根据设计的预浓缩时间进行调整。除了高精度和准确性外,所提出的分析系统还具有高度集成的优点,需要常规的现场准备、低能量供应和简单的辅助设备,适合现场操作。与其他常见的现场应用分子光谱仪器相比,FAFS固有的高选择性和多元素适用性突出了所提出分析系统的优越性和潜力。该系统成功应用于中国福建厦门附近沿海水体中溶解Mn的现场车载测定,还用于分析从中国福建九龙江口采集的天然水样。