Influence of different forms and materials (zirconia or titanium) of abutments in peri-implant soft-tissue healing using matrix metalloproteinase-8: A randomized pilot study.

机构信息

Senior Resident, Department of Prosthodontics, Center for Dental Education and Research, All India Institute of Medical Sciences New Delhi, New Delhi, India.

Professor, Department of Prosthodontics, Center for Dental Education and Research, All India Institute of Medical Sciences New Delhi, New Delhi, India.

出版信息

J Prosthet Dent. 2017 Oct;118(4):475-480. doi: 10.1016/j.prosdent.2016.11.017. Epub 2017 Mar 24.

Abstract

STATEMENT OF PROBLEM

It is unclear how pathogenic bacteria adhere to different implant materials and whether biomarker matrix metalloproteinase-8 (MMP-8) level provides a reliable method of evaluating the connective tissue status of peri-implant tissues.

PURPOSE

The purpose of this pilot clinical study was to evaluate peri-implant connective tissue response by assessing the MMP-8 levels in peri-implant crevicular fluid around titanium and zirconia abutments.

MATERIAL AND METHODS

The study was designed as a prospective, within-subject comparison with left-right randomization low. Twelve participants with partial edentulism were selected according to inclusion and exclusion criteria. Peri-implant sulcal fluid sampling and pocket probing depths were assessed at 1, 3, and 12 months after placing the abutments. The MMP-8 protein level of the peri-implant sulcal fluid was determined by MMP-8-specific sandwich enzyme-linked immunosorbent assay system. The independent t test or Wilcoxon test was used to compare MMP-8 levels and probing depth assessment between the zirconia and titanium groups at different time points (1, 3, and 12 months). Repeated measures ANOVA was used for within-group comparison of the MMP-8 levels at 3 time points (α=.05).

RESULTS

At 1 and 3 months, the titanium abutments showed significantly higher MMP-8 levels and probing depths than the zirconia abutments (P<.05), but no significant differences were found at 12 months for either variable (P>.05).

CONCLUSIONS

This study suggests the presence of more remodeling and/or inflammatory phenomena around titanium implant abutments than around zirconia abutments of a different design during the early stages but not at 1 year.

摘要

问题陈述

目前尚不清楚致病菌如何黏附在不同的植入材料上,以及生物标志物基质金属蛋白酶-8(MMP-8)水平是否提供了一种可靠的方法来评估种植体周围组织的结缔组织状态。

目的

本临床研究旨在通过评估钛和氧化锆基台周围龈沟液中的 MMP-8 水平,评估种植体周围结缔组织的反应。

材料和方法

该研究设计为前瞻性、左右随机低的自身对照研究。根据纳入和排除标准,选择了 12 名患有部分牙列缺失的参与者。在放置基台后 1、3 和 12 个月评估种植体周围沟液采样和探诊深度。通过 MMP-8 特异性夹心酶联免疫吸附测定系统测定龈沟液中 MMP-8 蛋白水平。采用独立 t 检验或 Wilcoxon 检验比较不同时间点(1、3 和 12 个月)氧化锆和钛基台之间 MMP-8 水平和探诊深度评估。采用重复测量方差分析对 3 个时间点的 MMP-8 水平进行组内比较(α=.05)。

结果

在 1 个月和 3 个月时,钛基台的 MMP-8 水平和探诊深度明显高于氧化锆基台(P<.05),但在 12 个月时两种变量均无差异(P>.05)。

结论

本研究表明,在早期阶段,与不同设计的氧化锆基台相比,钛种植体基台周围存在更多的重塑和/或炎症现象,但在 1 年后并非如此。