Eldarrat Aziza, High Alec, Kale Girish
Department of Postgraduation, City of London Dental School, London, UK.
Department of Diagnostic Services, Leeds Dental Institute, Leeds, UK.
Dent Res J (Isfahan). 2017 Jan-Feb;14(1):25-31. doi: 10.4103/1735-3327.201130.
The aim of this study was to investigate the influence of sodium chloride (NaCl) content in electrolyte solution on electrochemical impedance measurements of human dentin by employing electrochemical impedance spectroscopy.
Dentin samples were prepared from extracted molars. Electrochemical impedance measurements were carried out over a wide frequency range (0.01Hz-10MHz). After measurements, samples were characterized using scanning electron microscopy.
Electrochemical impedance measurements showed that the mean values of dentin electrical resistance were 4284, 2062, 1336, 53 and 48kΩ at different NaCl contents in electrolyte solution. One-way ANOVA test of mean values of dentin electrical resistance revealed a significant difference ( < 0.0001) as a function of NaCl content in electrolyte solution. Comparing electrical resistance values of dentin samples at 0.05% w/v and 0.9% w/v concentrations were found to be significantly different ( < 0.05 at 95% confidence level). Scanning electron microscopy revealed structure of dentin sample with intertubular dentin matrix and distribution of patent dentinal tubules.
This study indicated, through electrochemical impedance spectroscopy measurements, that electrical resistance of dentin was affected by the concentration of NaCl in electrolyte solution. It is clear from the current study that NaCl concentration in electrolyte solution has a marked influence on dentin electrical resistance. Therefore, this baseline data need to be considered in any future study on dental samples.
本研究旨在通过电化学阻抗谱研究电解质溶液中氯化钠(NaCl)含量对人牙本质电化学阻抗测量的影响。
从拔除的磨牙制备牙本质样本。在较宽的频率范围(0.01Hz - 10MHz)内进行电化学阻抗测量。测量后,使用扫描电子显微镜对样本进行表征。
电化学阻抗测量表明,在电解质溶液中不同NaCl含量下,牙本质电阻的平均值分别为4284、2062、1336、53和48kΩ。牙本质电阻平均值的单因素方差分析显示,作为电解质溶液中NaCl含量的函数存在显著差异(<0.0001)。发现在0.05% w/v和0.9% w/v浓度下牙本质样本的电阻值存在显著差异(在95%置信水平下<0.05)。扫描电子显微镜揭示了具有管间牙本质基质的牙本质样本结构以及开放牙本质小管的分布。
本研究通过电化学阻抗谱测量表明,牙本质的电阻受电解质溶液中NaCl浓度的影响。从当前研究可以清楚地看出,电解质溶液中的NaCl浓度对牙本质电阻有显著影响。因此,在未来任何关于牙齿样本的研究中都需要考虑这些基线数据。