The alternating current impedance characteristics of a uni-directional porous glass membrane and serial sections of dentin from unerupted human third permanent molars (with and without smear layers) were measured. The membrane was equilibrated at 20 +/- 1 degrees C in a range of concentrations of unbuffered KCl, and the tooth sections were equilibrated in 0.1 mmol/L unbuffered KCl. Each section's impedance was measured for a 50-mV (rms) alternating potential difference applied over 1 Hz to 65 kHz. By means of complex non-linear least-squares regression analysis, the dc resistance of each specimen was determined. Scanning electron microscopy and subsequent image analysis enabled the cross-sectional area of the pores in the membrane and dentin tubule surface-openings to be measured. The results showed that the measured cross-sectional area of pores in the membrane was in good agreement with that calculated from the measured dc resistance and solution resistivity over the range of electrolyte concentrations. In dentin, the presence of smear layers on the cut surfaces increased the measured resistance. The resistance of the smear layer varied, suggesting that its thickness changed across the surface of the dentin. This was superimposed on regional variations in resistance of smear-free dentin which were found to be related to alterations in the number of tubules present and their cross-sectional area. The resistivities of the dentin tubule contents and smear layer material were generally lower than that of the hydrating electrolyte. It is postulated that this could be due to ions from partial dissolution of the mineral in the dentin.

摘要

测量了单向多孔玻璃膜以及未萌出的人类第三恒磨牙牙本质连续切片(有和没有玷污层)的交流阻抗特性。将该膜在一系列未缓冲的氯化钾浓度中于20±1℃下平衡,而牙本质切片在0.1 mmol/L未缓冲的氯化钾中平衡。对每个切片施加50 mV(均方根)的交流电势差,频率范围为1 Hz至65 kHz,测量其阻抗。通过复非线性最小二乘回归分析,确定每个标本的直流电阻。扫描电子显微镜及后续图像分析能够测量膜中孔隙和牙本质小管表面开口的横截面积。结果表明,在电解质浓度范围内,膜中孔隙的测量横截面积与根据测量的直流电阻和溶液电阻率计算得出的结果高度一致。在牙本质中,切割表面上玷污层的存在增加了测量电阻。玷污层的电阻各不相同,表明其厚度在牙本质表面上有所变化。这叠加在无玷污牙本质电阻的区域差异上,发现这种差异与存在的小管数量及其横截面积的改变有关。牙本质小管内容物和玷污层材料的电阻率通常低于水合电解质的电阻率。据推测,这可能是由于牙本质中矿物质部分溶解产生的离子所致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验