Suppr超能文献

Successful Extubation Using Heliox BiPAP in Two Patients with Postextubation Stridor.

作者信息

Punj Pragya, Nattanmai Premkumar, George Pravin, Newey Christopher R

机构信息

Department of Neurology, University of Missouri, 5 Hospital Drive, CE 540, Columbia, MO 65211, USA.

Cleveland Clinic, Cerebrovascular Center, Neurological Institute, 9500 Euclid Avenue, Cleveland, OH 44195-5245, USA.

出版信息

Case Rep Pulmonol. 2017;2017:1253280. doi: 10.1155/2017/1253280. Epub 2017 Mar 8.

Abstract

Postextubation stridor is associated with significant morbidity. It commonly results in extubation failure after established medical treatment fails, such as nebulized epinephrine and/or intravenous steroids. The role of heliox (i.e., combination of helium and oxygen) in managing patients with postextubation stridor has not been fully established. We report two cases of postextubation stridor successfully treated with heliox delivered with bilevel positive airway pressure (BiPAP) after failure of standard medical therapy.