锥形束计算机断层扫描的灰度值与多层螺旋计算机断层扫描的亨氏单位比较:一项研究。

Comparison of gray values of cone-beam computed tomography with hounsfield units of multislice computed tomography: An study.

作者信息

Patrick Sanjana, Birur N Praveen, Gurushanth Keerthi, Raghavan A Shubhasini, Gurudath Shubha

机构信息

Department of Oral Medicine and Radiology, KLE Society's Institute of Dental Sciences, Bengaluru, Karnataka, India.

出版信息

Indian J Dent Res. 2017 Jan-Feb;28(1):66-70. doi: 10.4103/ijdr.IJDR_415_16.

Abstract

PURPOSE

Hounsfield unit (HU) provides a quantitative evaluation of bone density. The assessment of bone density is essential for successful treatment plan. Although, multislice computed tomography (MSCT) is considered as gold standard in evaluating bone density, cone-beam computed tomography (CBCT) is frequently used in dentomaxillofacial imaging due to lower radiation dose, less complex device, and images with satisfactory resolution.

AIMS AND OBJECTIVES

The aim of this study is to determine and compare the gray value and HU value of hypodense and hyperdense structures on CBCT and MSCT, respectively. The study also evaluated and compared the gray values in different field of views within CBCT.

MATERIALS AND METHODS

A total of 20 dry human mandibles were obtained. The gray values and HU values of hypodense structures (extraction socket, inferior alveolar canal, and mental foramen) and hyperdense structures (enamel, cancellous, and cortical bone) were evaluated and compared between CBCT and MSCT images, respectively. The obtained data were statistically analyzed.

STATISTICAL ANALYSIS

One-way analyses of variance, ANOVA F-test.

RESULTS

The gray value for hypodense structures in large volume CBCT scans resembled the HU value. The study showed statistically significant difference (P < 0.001) in gray values for all the hyperdense structures in CBCT when compared to HU values of MSCT scans.

CONCLUSION

The gray value for hypodense structures in large volume CBCT scan was more reliable and analogous to HU value in MSCT. The determination of grey values in CBCT may not be as accurate as HU value in CT for hyperdense structures.

摘要

目的

亨氏单位(HU)可对骨密度进行定量评估。骨密度评估对于成功制定治疗方案至关重要。尽管多层螺旋计算机断层扫描(MSCT)被视为评估骨密度的金标准,但锥形束计算机断层扫描(CBCT)因辐射剂量较低、设备不太复杂且图像分辨率令人满意,而经常用于牙颌面成像。

目的

本研究的目的是分别确定并比较CBCT和MSCT上低密度和高密度结构的灰度值和HU值。该研究还评估并比较了CBCT内不同视野的灰度值。

材料与方法

共获取20具干燥的人类下颌骨。分别在CBCT和MSCT图像上评估并比较低密度结构(拔牙窝、下牙槽神经管和颏孔)和高密度结构(牙釉质、松质骨和皮质骨)的灰度值和HU值。对所得数据进行统计分析。

统计分析

单因素方差分析,方差分析F检验。

结果

大视野CBCT扫描中低密度结构的灰度值与HU值相似。与MSCT扫描的HU值相比,该研究显示CBCT中所有高密度结构的灰度值存在统计学显著差异(P < 0.001)。

结论

大视野CBCT扫描中低密度结构的灰度值更可靠,且与MSCT中的HU值类似。对于高密度结构,CBCT中灰度值的测定可能不如CT中的HU值准确。