使用Amplatzer房间隔封堵器经导管封堵房间隔缺损后冠状静脉窦缺损:装置潜在侵蚀作用

Coronary Sinus Defect Following Transcatheter Closure of ASD Using Amplatzer Septal Occluder: Potential Erosion by the Device.

作者信息

Mohammad Nijres Bassel, Al-Kubaisi Maytham, Bokowski John, Abdulla Ra-Id, Awad Sawsan

机构信息

Rush Center for Congenital Heart Disease, Rush University Children's Hospital, 1625 W. Harrison St, Kellogg Building, Suite 608, Chicago, IL, 60612, USA.

出版信息

Pediatr Cardiol. 2017 Jun;38(5):1084-1086. doi: 10.1007/s00246-017-1613-x. Epub 2017 Apr 10.

Abstract

We present a case of small coronary sinus defect detected after transcatheter device closure of a large secundum atrial septal defect. Although device erosion of the dilated coronary sinus is suspected, the defect in the coronary sinus may have been present prior to ASD device closure. Dilated coronary sinus may be a risk factor when closing a secundum ASD with a device. To the best of our knowledge, coronary sinus erosion by an ASD device has not yet been reported in the medical literature.

摘要

我们报告一例在经导管装置闭合大型继发孔房间隔缺损后发现的小冠状静脉窦缺损病例。尽管怀疑扩张的冠状静脉窦存在装置侵蚀,但冠状静脉窦的缺损可能在房间隔缺损装置闭合之前就已存在。在用装置闭合继发孔房间隔缺损时,扩张的冠状静脉窦可能是一个危险因素。据我们所知,医学文献中尚未报道过房间隔缺损装置导致冠状静脉窦侵蚀的情况。