Tu Fung-Chao, Sun Hsu-Dong, Ting Wan-Hua, Wu Wen-Yih, Lin Ho-Hsiung, Hsiao Sheng-Mou
*Department of Obstetrics and Gynecology, Far Eastern Memorial Hospital, Banqiao, New Taipei †Department of Obstetrics and Gynecology, National Taiwan University College of Medicine and National Taiwan University Hospital, Taipei ‡Graduate School of Biotechnology and Bioengineering, Yuan Ze University, Taoyuan, Taiwan.
Surg Laparosc Endosc Percutan Tech. 2017 Jun;27(3):e31-e35. doi: 10.1097/SLE.0000000000000398.
The aim of this study was to evaluate the efficacy and feasibility of a novel pusher device for performing extracorporeal knot tying. Each of the 3 laparoscopists randomly performed 10 device-assisted double sheet bends (the device group), ten 4s modified Roeder sliding knots (the sliding group), and 10 laparoscopic traditional extracorporeal static surgeon's knots (the static group). All knots and 5 unknotted threads were measured for strength. The device group had higher knot strength, lower knotting failure rate, and shorter knotting time compared with the sliding group. The knot strengths of the successful knots in the device group were consistent with those obtained in the static group, and higher than the sliding group. Our laparoscopic novel pusher device should be an effective device in assisting knot tying with the advantages of steady and strong knot strength, lower failure rate, and shorter knotting time.
本研究的目的是评估一种新型推送装置用于体外打结的有效性和可行性。3名腹腔镜医师每人随机进行10次器械辅助双平结(器械组)、10次4号改良Roeder滑结(滑结组)和10次腹腔镜传统体外静态外科结(静态组)。对所有的结和5根未打结的线进行强度测量。与滑结组相比,器械组的结强度更高、打结失败率更低且打结时间更短。器械组成功打结的强度与静态组一致,且高于滑结组。我们的腹腔镜新型推送装置应是一种有效的打结辅助器械,具有结强度稳定且牢固、失败率低和打结时间短的优点。