不同CT扫描仪型号和重建算法配置下肾结石体积测量的一致性

Consistency of Renal Stone Volume Measurements Across CT Scanner Model and Reconstruction Algorithm Configurations.

作者信息

Huang Alice E, Montoya Juan C, Shiung Maria, Leng Shuai, McCollough Cynthia H

机构信息

1 Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.

出版信息

AJR Am J Roentgenol. 2017 Jul;209(1):116-121. doi: 10.2214/AJR.16.16940. Epub 2017 Apr 12.

Abstract

OBJECTIVE

The objective of this prospective study is to evaluate the consistency of renal stone volume estimation using dual-energy CT across scanner model and reconstruction algorithm configurations.

SUBJECTS AND METHODS

Patients underwent scanning with routine kidney stone composition protocols on both second- and third-generation dual-source CT scanners. Images were reconstructed using filtered back projection and iterative reconstruction (IR). In addition, a modified IR kernel on the third-generation CT scanner was evaluated. Individual kidney stone volumes were determined and compared.

RESULTS

No significant difference was noted in measured volumes between filtered back-projection data, IR data from the second-generation scanner, and the modified IR kernel data (p > 0.05). The third-generation commercially available IR kernel yielded lower volumes than did the other configurations (p < 0.0001).

CONCLUSION

With the use of a modified kernel for the third-generation scanner, patients being monitored for changes in kidney stone volume can undergo scanning performed with second- or third-generation dual-energy CT scanners, and the images obtained can be reconstructed with either filtered back projection or IR without the introduction of bias into kidney stone volume measurements.

摘要

目的

本前瞻性研究的目的是评估在不同扫描仪型号和重建算法配置下,使用双能CT估算肾结石体积的一致性。

对象与方法

患者在第二代和第三代双源CT扫描仪上均采用常规肾结石成分分析方案进行扫描。图像采用滤波反投影法和迭代重建(IR)法重建。此外,还对第三代CT扫描仪上的一种改良IR内核进行了评估。确定并比较了各个肾结石的体积。

结果

滤波反投影数据、第二代扫描仪的IR数据与改良IR内核数据之间的测量体积无显著差异(p>0.05)。第三代商用IR内核得出的体积比其他配置的体积小(p<0.0001)。

结论

对于第三代扫描仪使用改良内核的情况,监测肾结石体积变化的患者可采用第二代或第三代双能CT扫描仪进行扫描,所获得的图像可用滤波反投影法或IR法重建,而不会在肾结石体积测量中引入偏差。

相似文献

1
Consistency of Renal Stone Volume Measurements Across CT Scanner Model and Reconstruction Algorithm Configurations.
AJR Am J Roentgenol. 2017 Jul;209(1):116-121. doi: 10.2214/AJR.16.16940. Epub 2017 Apr 12.
7
Iterative reconstructions versus filtered back-projection for urinary stone detection in low-dose CT.
Acad Radiol. 2013 Nov;20(11):1429-35. doi: 10.1016/j.acra.2013.08.009.
9

本文引用的文献

2
Quantification of asymptomatic kidney stone burden by computed tomography for predicting future symptomatic stone events.
Urology. 2015 Jan;85(1):45-50. doi: 10.1016/j.urology.2014.08.031. Epub 2014 Oct 22.
5
Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography.
J Comput Assist Tomogr. 2012 May-Jun;36(3):339-46. doi: 10.1097/RCT.0b013e31825586c0.
6
Automated volumetric assessment by noncontrast computed tomography in the surveillance of nephrolithiasis.
Urology. 2012 Jul;80(1):27-31. doi: 10.1016/j.urology.2012.03.009. Epub 2012 May 10.
7
Prevalence of kidney stones in the United States.
Eur Urol. 2012 Jul;62(1):160-5. doi: 10.1016/j.eururo.2012.03.052. Epub 2012 Mar 31.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验