Suppr超能文献

自适应统计迭代重建算法对冠状动脉计算机断层扫描血管造影图像质量的影响。

Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography.

作者信息

Precht Helle, Thygesen Jesper, Gerke Oke, Egstrup Kenneth, Waaler Dag, Lambrechtsen Jess

机构信息

Department of Medical Research, Odense University Hospital Svendborg, Svendborg, Denmark; Conrad Research Programme, University College Lillebelt, Odense, Denmark.

Department of Clinical Engineering, Central Denmark Region, Århus, Denmark.

出版信息

Acta Radiol Open. 2016 Dec 1;5(12):2058460116684884. doi: 10.1177/2058460116684884. eCollection 2016 Dec.

Abstract

BACKGROUND

Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure.

PURPOSE

To evaluate whether adaptive statistical iterative reconstruction (ASIR) enhances perceived image quality in CCTA compared to filtered back projection (FBP).

MATERIAL AND METHODS

Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA) and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR]) was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data.

RESULTS

VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR ( = 0.004). The objective measures showed significant differences between FBP and 60% ASIR ( < 0.0001) for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26.

CONCLUSION

ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

摘要

背景

冠状动脉计算机断层扫描血管造影(CCTA)需要高空间和时间分辨率,提高低对比度分辨率以评估冠状动脉狭窄、斑块检测和/或非冠状动脉病变。因此,已经开发了新的重建算法,特别是迭代重建(IR)技术,试图在不增加辐射暴露的情况下提高图像质量。

目的

评估与滤波反投影(FBP)相比,自适应统计迭代重建(ASIR)是否能提高CCTA中感知到的图像质量。

材料与方法

30例因疑似冠状动脉疾病接受CCTA检查的患者。图像采用FBP、30%ASIR和60%ASIR进行重建。90组图像由5名观察者使用主观视觉分级分析(VGA)进行评估,并通过比例优势模型进行评估。对对数转换后的数据进行线性混合效应建模,分析客观质量评估(对比度、噪声和对比度噪声比[CNR])。由于该研究仅涉及匿名收集的临床数据,当地伦理委员会豁免了伦理批准的要求。

结果

通过将FBP与ASIR进行比较,VGA显示清晰度有显著改善,30%ASIR的优势比为1.54,60%ASIR的优势比为1.89(P = 0.004)。客观测量显示,FBP与60%ASIR之间在噪声方面存在显著差异(P < 0.0001),估计比值为0.82,在CNR方面也存在显著差异,估计比值为1.26。

结论

ASIR改善了主观图像质量的参数清晰度,并且在客观上降低了噪声并提高了CNR。