Han Jang Hee, Kim Hong-Wook, Rha Koon Ho, Kim Jang Hwan
*Department of Urology, Severance Hospital, Urological Science Institute, Yonsei University College of Medicine, Seoul †Department of Urology, Konyang University College of Medicine, Daejeon, Korea.
Surg Laparosc Endosc Percutan Tech. 2017 Jun;27(3):e36-e39. doi: 10.1097/SLE.0000000000000407.
Extraperitoneal transvesicoscopic vesicovaginal fistula (VVF) repair has received limited use because of its narrow working space, longer operation time, and technical difficulty. The present study describes the feasibility of robotic-assisted transvesicoscopic VVF repair in an animal model. Two Yorkshire swine underwent robotic-assisted laparoscopic (RAL) VVF repair. With the 4 trocars, an artificial VVF was made in the supratrigonal area and VVF repair was performed in 3 layers as in open VVF repair methods. The mean operation time was 108 minutes. The operation time was prolonged in 1 case due to weak fixation of bladder to anterior abdominal wall. Equipment interference did not occur. Tissue manipulation and suturing were easy. The results of this study suggest that extraperitoneal RAL procedures for VVF repair may be an effective minimally invasive modality with reduced morbidity. A shorter operation time and easy suturing technique were the distinct merits of the extraperitoneal RAL technique.
腹膜外经膀胱镜膀胱阴道瘘(VVF)修补术由于其操作空间狭窄、手术时间长及技术难度大,应用有限。本研究描述了机器人辅助经膀胱镜VVF修补术在动物模型中的可行性。两只约克夏猪接受了机器人辅助腹腔镜(RAL)VVF修补术。通过4个套管针,在膀胱三角区上方制造人工VVF,并按照开放性VVF修补方法分3层进行VVF修补。平均手术时间为108分钟。1例因膀胱与前腹壁固定薄弱导致手术时间延长。未发生设备干扰。组织操作和缝合容易。本研究结果表明,腹膜外RAL技术用于VVF修补可能是一种有效的微创方式,可降低发病率。较短的手术时间和简便的缝合技术是腹膜外RAL技术的显著优点。