Electrophysiological Evaluation of Pulmonary Vein Isolation.

作者信息

Kircher S, Sommer P

机构信息

Heart Center, University of Leipzig, Department of Electrophysiology, Leipzig, Germany.

出版信息

J Atr Fibrillation. 2013 Oct 31;6(3):934. doi: 10.4022/jafib.934. eCollection 2013 Oct-Nov.

Abstract

Since the pulmonary veins (PVs) were identified as a major source of AF triggers, ablation strategies targeting the PVs have evolved from focal ablation inside the PVs to wide area circumferential PV isolation (PVI) which at this juncture is the standard approach. Despite the widespread popularity of PVI, a universal definition is lacking. While "entrance block" is a generally accepted endpoint for PVI, the role of "exit block" has yet to be determined. Inexcitability of the circular ablation line has been introduced as a promising additional endpoint for PVI and was associated with an improved clinical outcome in a randomized trial. Correct interpretation of PV electrograms during an ablation procedure is critical in terms of efficacy and safety. A variety of electrophysiological techniques help to correctly differentiate components of complex PV electrograms. Resumption of PV conduction after initially successful PVI leading to AF recurrence remains a major problem and confirmation of bi-directional conduction block does not exclude reversible tissue damage along the ablation line. Prolongation of post-PVI monitoring and application of provocative procedures such as the administration of adenosine after initial PVI to unmask dormant PV conduction may improve clinical outcome although there is lack of valid data supporting these strategies. This article aims on clarifying the electrophysiological criteria for complete pulmonary vein isolation and the explain the importance of this cornerstone in almost all atrial fibrillation ablation procedures.

摘要

自从肺静脉(PVs)被确定为房颤触发因素的主要来源以来,针对肺静脉的消融策略已从肺静脉内的局灶性消融发展为广泛的肺静脉环周隔离(PVI),目前这是标准方法。尽管PVI广受欢迎,但缺乏统一的定义。虽然“入口阻滞”是PVI普遍接受的终点,但“出口阻滞”的作用尚未确定。环形消融线的不可兴奋性已被引入作为PVI一个有前景的额外终点,并且在一项随机试验中与改善的临床结果相关。在消融过程中正确解读肺静脉电图对疗效和安全性至关重要。多种电生理技术有助于正确区分复杂肺静脉电图的成分。最初成功的PVI后肺静脉传导恢复导致房颤复发仍然是一个主要问题,并且双向传导阻滞的确认并不排除沿消融线的可逆性组织损伤。延长PVI后的监测以及在初始PVI后应用激发程序,如给予腺苷以揭示潜伏的肺静脉传导,可能会改善临床结果,尽管缺乏支持这些策略的有效数据。本文旨在阐明完全肺静脉隔离的电生理标准,并解释这一基石在几乎所有房颤消融手术中的重要性。

相似文献

1
Electrophysiological Evaluation of Pulmonary Vein Isolation.肺静脉隔离的电生理评估
J Atr Fibrillation. 2013 Oct 31;6(3):934. doi: 10.4022/jafib.934. eCollection 2013 Oct-Nov.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验